BAT Antenna Guide BAT
Release 09 05/2015
53
BAT-ANT-N-LC-G-100m-IP65
Order Number: 943 981-101
Configurations Longitudinal Attenuation
Cable length
100 m, 328 ft
Cable specification
2 × N male connectors; 0.15 dB at 2.4 GHz
Table 53: Specification
Frequency band
2000 MHz - 2900 MHz
Antenna connector
N-type male
Table 54: Radio technology
Operating temperature
−
40 ºF ... +185 ºF (
−
40 ºC ... +85 ºC)
Storage/transport temperature
−
70 ºC ... +85 ºC
Dimensions
328 ft (100 m); d = 0.6 in (15 mm)
Protection class
IP65
Weight 53 lb
(24 kg)
Table 55: Ambient conditions
Halogen free and flame retardant outer sheath
Low corrosive gas emission according to IEC 60754-2
Flame retardant according to IEC 60332-1 and IEC 60332-3 cat. C
Low smoke emission according to IEC 61034
Table 56: Flammability Characteristics
Leaky Cable
2 × N-connector, preassembled
1 × terminating resistor 50 Ohm
100 × fastening clip
Table 57: Scope of delivery and accessories
db/328 ft (dB/100 m)
LC at 4 in (10 cm) from a concrete floor
15
LC at 0.6 in (15 mm) from a metal surface 17
LC directly against a metal surface
34
Table 58: Longitudinal attenuation of both cables between 2.4 and 2.485 GHz
Summary of Contents for 942 047-001