- hold the key of the starter switch turned until the engine is started, but not longer than 20
seconds; if the engine fails to start, carry out a repeated start-up not earlier than after one
minute;
- after the engine is started, release the clutch pedal, check functioning of all signal
lamps and gauge indications (coolant temperature, oil pressure in the engine, on-board
circuit voltage, etc.). Let the engine run at low rpm until pressure stabilizes within gauge
operation range. Actually measured parameters and operation states of tractor systems
and units are displayed on the integrated indicator, on the dashboard, on the pilot lamp
unit, on the control panel of the rear axle DL, of FDA drive, on the engine control system
panel and on the information screen. The troubleshooting annunciator of RLL electronic
control system lights up on RLL control panel - it indicates the workability and blocking of
the RLL control system;
- in case the tractor is equipped with GB 24x12, after the engine start a LED lamp of
green color lights up on the handle of GB reduction unit gear and pass shifting lever, and
the annunciator of GB reduction unit lower pass activation lights up on the control panel of
rear axle DL and FDA drive indicating the GB reduction unit lower pass activation;
- a pilot lamp indicating the charge of additional AB with the voltage of 24W shall go out
after the engine start – it indicates that the additional AB with the voltage of 24W is being
charged through the voltage converter. If the pilot lamp indicating the charge continues to
glow after the engine start – it indicates that the additional AB is not being charged and it is
required to eliminate the failure.
IT IS FORBIDDEN TO OPERATE THE TRACTOR IN CLOSED ROOMS WITHOUT
REQUIRED VENTILATION (AIR EXCHANGE). EXHAUST GASES MAY LEAD TO A LE-
THAL OUTCOME!
IT IS FORBIDDEN TO RUN THE ENGINE WITH THE SYSTEMS OF COOLING AND
ENGINE LUBRICATION UNFILLED!
ATTENTION: THE TRACTOR CAB IS EQUIPPED WITH A SINGLE-OCCUPANCY SEAT
AND THE OPERATOR IS THE ONLY PERSON TO STAY IN!
ATTENTION: START THE ENGINE AND INSPECT GAUGES ONLY WHEN STAYING IN
THE OPERATOR'S SEAT!
ATTENTION: REMEMBER THAT THE ENGINE START IS POSSIBLE ONLY WHEN THE
RANGE SHIFTING LEVER IS SET INTO A NEUTRAL POSITION!
ATTENTION: WHILE STARTING THE ENGINE, THERE MUST BE NO PEOPLE UNDER,
IN FRONT OF AND BEHIND THE TRACTOR, AS WELL AS BETWEEN THE TRACTOR
AND AN IMPLEMENT COUPLED TO IT!
IT IS FORBIDDEN TO START THE ENGINE TAKING THE TRACTOR IN TOW, AS IT
MAY RESULT IN ENGINE BREAKDOWN. START THE ENGINE ONLY WHEN YOU
STAY IN THE OPERATOR'S SEAT!