4.1 TECHNICAL SPECIFICATIONS NCIM10-NCIM18 (115/1/60)
D R Y E R M O D E L
NCIM10
NCIM18
Air flow rate at nominal condition
1
[scfm]
[Nl/min]
[Nm
3
/h]
10
285
17
15
425
26
Pressure DewPoint at nominal condition
1
[°F - °C]
38 – 3.3
Nominal ambient temperature
[°F - °C]
100 - 37.8
Max. ambient temperature
[°F - °C]
115 – 45
Min. ambient temperature
[°F - °C]
34 – 1
Nominal inlet air temperature
[°F - °C]
100 - 37.8
Max. inlet air temperature
[°F - °C]
115 – 45
Nominal inlet air pressure
[psig – barg]
100 - 6.9
Max. inlet air pressure
[psig - barg]
232 – 16
Max. outlet air pressure drop -
∆
p
[psi – bar]
4.4 - 0.3
Inlet-outlet air connection
Copper pipe OD 3/8 in. (9.52 mm)
Refrigerant type
R134.a (HFC) - CH
2
F-CF
3
Refrigerant charging
[oz – g]
6.1/8 - 175
12.3/8 - 350
Cooling air capacity
[cfm - m
3
/h]
120 - 200
200 - 340
Power supply
[Phase/V/Hz]
115/1/60
Nominal electric consumption
[A]
2.2
3.2
Max. electric consumption
[A]
2.5
4.1
Compressor power
[HP]
1/8
1/5
Weight
[lbs - kg]
62 - 28
68 - 31
Max. noise level
< 70 dbA at 40in (1m)
1
The nominal condition refers to an ambient temperature of 100°F with inlet air at 100 psig and 100°F
1
2
OUTLET
INLET
I
H
I
3
A
C
E
F
B
D
B
A
G
J
Sortie
Entrée
Inches
mm
A
14.562
370
B
17.625
449
C
17.437
443
D
2.500
65
E
1.375
35
F
2.00
51
G
2.750
69
H
15.562
395
I
1.062
27
J
2.437
62
K
.375
10
L
1.00
26
M
.562
14
1-Rocker On/Off Switch-Illuminated
2-Power Supply Cord
3-Condensate Drain