Installation
METPOINT
®
SP11
15
11 Installation
11.1 Installation instructions
Warning!
Risk of injury in the event of insufficient qualifications!
Improper use can lead to significant personal injury and material damage.
All of the activities described in these operating instructions must only be carried out by qualified
personnel with the qualifications described hereinafter.
Qualified personnel
Due to the specific training and knowledge concerning the measuring and control technology, and due to
their experience and knowledge of the country-specific provisions, standards in force and directives, qualified
personnel are capable of carrying out the described work and of independently identifying the possible risks.
Special employment conditions require further corresponding knowledge, e.g. regarding aggressive media.
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air
or through bursting and/or unsecured plant components.
Measures:
•
Only carry out installation works when the system is pressureless.
•
Only use pressure-resistant installation material.
•
Do not exceed the max. operating pressure (see type plate).
•
Check the installation point for tightness subsequent to installation.
Warning!
Risk of injury through temperature!
Risk of injury through the contact with very high or low temperatures.
Measures:
•
Prior to installation or removal of the pressure transducer, carry out a temperature compensation or
wear protective gloves.
Note:
It is imperative to observe all of the listed hazard and warning notes.
Please also observe all the provisions and instructions regarding the occupational safety and fire
at the respective point of installation.
As a matter of principle, only use suitable tools and material in a proper
condition.
Bear in mind that condensates can contain aggressive and harmful components.
Therefore, avoid contact with the skin.
Caution!
Malfunction at the pressure transducer!
Through incorrect installation, malfunctions may occur at the METPOINT
®
PRM pressure trans-
ducer. These can lead to incorrect measuring results and to misinterpretations.