Installation and operating manual
EN
24
METPOINT
®
SF53
4.3.2. Current output 4 ... 20 mA, 3-wire
Connection by means of plug-type connector A.
Connection diagram for METPOINT
®
SF53 and METPOINT
®
BDL
METPOINT
®
FLM SFxx
METPOINT
®
BDL
BROWN
GREY
q
BLUE
I
4 ... 20 mA
3
2
1
5
1
2
3
4
5
6
7
8
9
V
- U
V
V
+ U
OUT
+ I
Pin assignment - sensor
Function
Wire colour
Pin assignment - BDL
PIN-1
+ U
V
Plus (+) connection, power supply
brown
PIN-7
+ U
V
PIN-5
+ I
OUT
Current output
grey
PIN-4
Analog IN (+)
PIN-3
- U
V
Minus (-) connection, power supply
blue
PIN-8
- U
V
PIN-2
not assigned
white
PIN-4
not assigned
black
4.3.3. Galvanically isolated pulse output
Connection by means of plug-type connector B.
Connection diagram for METPOINT
®
SF53 and METPOINT
®
BDL
METPOINT
®
FLM SFxx
METPOINT
®
BDL
q
R = 4,7kΩ
BROWN
BLACK
GREY
BLUE
1
4
5
3
Impuls
V
U
+
V
U
+
V
U
-
V
-
U
V
1
2
3
4
5
6
7
8
9
R
Pin assignment - sensor
Function
Wire colour
Pin assignment - BDL
PIN-1
+ U
V
Plus (+) connection, power supply
brown
PIN-4
Pulse
Pulse
black
PIN-4
Analog IN (+)
PIN-5
Pulse
Pulse
grey
PIN-7
+ U
V
PIN-3
- U
V
Minus (-) connection, power supply
blue
PIN-2
not assigned
white