Transport
DRYPOINT® RA HT 20-350 NA UL
11
6
Transport
Check the packaging for visible loss or damage. If no visible damage can be ascertained, place the unit in close proximity
to the place of installation and unpack the device.
During this procedure, the dryer must always remain in an upright position. The components may be damaged when the
unit is tilted or turned upside down.
Store the device in a dry environment and do not expose it to extreme weather conditions.
Handle with care. Strong shocks can cause irreparable damage.
7
Storage
Keep the device away from extreme weather conditions
even when packaged.
Keep the dryer in an upright position, also while it is stored.
Tilting the device or turning it upside down can cause
irreparable damage to some components.
When the dryer is not in use, it can be stored in its
packaging in a dust-free and protected place at a
temperature of
+34°F (+1°C) … +122°F (+50°C) and at a
specific humidity of max. 90%. If the storage period
exceeds 12 months, you should contact the manufacturer.
The packaging material is recyclable. Dispose of the material in accordance with the
directives and provisions in force in the country of destination
8
Installation
8.1
Place of installation
Note!
Ambient conditions!
In the event that the dryer is not installed under suitable ambient conditions, the ability of the device to
condense refrigerant gas is impaired. This can result in a higher load of the refrigerating compressor, and in
a loss of efficiency and performance of the dryer.
This in turn leads to overheated condenser fan motors, to malfunction of electric components and to a
breakdown of the dryer. Failures of this type will affect warranty considerations.
Do not install the dryer in an environment in which chemicals with a corrosive effect, explosive gases, toxic
gases, evaporation heat, high ambient temperatures or extreme dust and dirt can be found.
In case of
fire
, use an approved fire extinguisher,
water
is not an acceptable means in cases of
fire.
Minimum installation requirements
:
•
Select a clean dry area, free from dust, and protected
from atmospheric disturbances.
•
The supporting area must be smooth, horizontal and able
to hold the weight of the dryer.
•
Minimum ambient tempe34 °F (+1 °C).
•
Maximum ambient tempe
120°F (50°C)
.
•
Allow at least a clearance of 40 in (1m) on each side of
the dryer for proper ventilation and to facilitate eventual
maintenance operations.
The dryer does not require attachment to the floor surface;
however installations where the unit is suspended require
an attachment to the hanging apparatus.
Do not obstruct the ventilation grille (not even partially).
Prevent any recirculation of the outgoing cooling air.
Protect the dryer against draughts.
SC
C0
00
1
40in - 1
m
40
in
-
1
m
40in - 1
m
40in
- 1m
20-50
1i
n
-
26
m
m
1/2in - 14mm
3/8in - 10mm
14in - 354mm
LGT
00
1
2
1.
1
/4
in
30
m
m
Summary of Contents for DRYPOINT RA HT 100-P NA UL
Page 19: ...DRYPOINT RA HT 20 350 NA UL 19 10 2 Technical data DRYPOINT RA HT 150 350 NA E 1 230 60 UL ...
Page 34: ...Appendices 34 DRYPOINT RA HT 20 350 NA UL 13 1 2 Dryers Dimensions DRYPOINT RA HT 75 NA UL ...
Page 35: ...Appendices DRYPOINT RA HT 20 350 NA UL 35 13 1 3 Dryer dimensions DRYPOINT RA HT 100 NA UL ...
Page 36: ...Appendices 36 DRYPOINT RA HT 20 350 NA UL 13 1 4 Dryer dimensions DRYPOINT RA HT 150 NA UL ...
Page 46: ...Appendices 46 DRYPOINT RA HT 20 350 NA UL 13 3 2 Electric diagram DRYPOINT RA HT 20 50 NA UL ...
Page 47: ...Appendices DRYPOINT RA HT 20 350 NA UL 47 13 3 3 Electric diagram DRYPOINT RA HT 75 100 NA UL ...
Page 48: ...Appendices 48 DRYPOINT RA HT 20 350 NA UL 13 3 4 Electric diagram DRYPOINT RA HT 150 NA UL ...
Page 51: ...Appendices ...