26 / EN
Dryer / User Manual
Maintenance and cleaning
3-If there is lint accumulation in the funnel
of the water tank, clean it under running
water.
4-Place the water tank into its seat.
7.3 For the condenser;
Hot and humid air in the condenser is cooled
with the cold air from the room. Thus,
the humid air circulating in your dryer is
condensed and then pumped into the tank.
C
Clean the condenser after every
30 drying cycles or once a month.
To clean the condenser:
1. If a drying process has been carried out,
open the door of the machine and wait
until it cools down.
2. Unlock the 2 condenser locks after
opening the kick plate.
3. Pull out the condenser.
4. Clean the condenser by applying
pressurized water with a shower
armature and wait until the water drains.
5. Place the condenser in its housing. Fasten
the 2 locks and make sure that they are
seated securely.
6. Close the kick plate cover.