CLEARPOINT V
®
Series Activated Carbon Tower
(Rev. D)
7
Unit ratings adhere to the following inlet conditions per ISO 7183, Table 2, Option A2:
+ Inlet Compressed Air Temperature 100 °F (38 °C)
+ Inlet Compressed Air Pressure 100 psig (7 bar)
+ Maximum Ambient Air Temperature 100 °F (38 °C)
+ Inlet Compressed Air Relative Humidity 100% (Saturated)
SCFM is defined as the volume of free air in cubic feet per minute measured at 14.696 psia (1.013 bara) at 68 °F (20 °C)
temperature with 0% relative humidity (0 WVP).
3.2
Correction Factors
Correction Factors
60 psig 70 psig 80 psig 90 psig 100 psig 110 psig 120 psig 130 psig 140 psig 150 psig
correction
factor
0.65
0.74
0.83
0.91
1.00
1.12
1.16
1.20
1.25
1.29
How to determine adsorber capacity at operating conditions: How to select the adsorber for actual conditions:
ADJUSTED CAPACITY =
ADJUSTED CAPACITY =
Standard Flow Rate x Correction Factor
System Flow Rate ÷ Correction Factor
Example:
Example:
Adsorber Model:
CLEARPOINT® V 250
System Flow Rate: 300 scfm
Standard Flow Rate:
250 scfm
Operating Conditions:
130 psig
Operating Conditions: 110 psig / 110 °F
ADJUSTED CAPACITY = 300 scfm ÷ 1.20 =
250 scfm
ADJUSTED CAPACITY = 250 scfm x 1.12 -
280 scfm
Select Model:
CLEARPOINT® V 250