![Beko BX 109 AC Installation Manual Download Page 38](http://html.mh-extra.com/html/beko/bx-109-ac/bx-109-ac_installation-manual_27611038.webp)
38 / 88 EN
Mobile room air conditioner / Installation Manual
To save the cost of a service call, please try the suggestions below to see if you can solve your problem
without outside help.
Air condition will not operate
Causes
Solutions
•
The power switch is released.
•
Switch on the power.
•
Power supply failure.
•
Wait for the recovery of power supply.
•
The fuse is burnt.
•
Replace the fuse by professional.
•
It doesn't reach the setting time for starting
up.
•
Wait or eliminate the original setting.
Unit doesn’t start when pressing ON/OFF button
Causes
Solutions
•
It is not four minutes after switch off.
•
Wait four minutes.
•
Room temperature is lower than the setting
temperature under cooling mode or higher
than setting temperature under heating mode.
•
Reset the setting temperature.
The wind blowing out, but the cooling/heating effect is bad
Causes
Solutions
•
Mistakes in temperature setting.
•
Set a proper temperature, setting temperature
should be lower than ambient temperature.
•
The air filter is blocked by dust.
•
Clean the air filter.
•
The air inlet or outlet of machine is blocked.
•
Remove the obstruction.
•
Turn the air conditioner on in very hot room.
•
Allow additional time to remove stored heat
from walls ,ceiling, floor and furniture.
•
Cooling capacity is insufficient.
•
Reconfirm the required cooling/heating.
capacity with your dealer.
•
The doors or windows are open.
•
Close the doors and windows.
Noise or vibration
Causes
Solutions
•
The ground is not level or not flat enough.
•
Place the unit on a flat, level ground if possible.
9
Troubleshooting