Free match split type air conditioner / Installation Manual
17 / 44 EN
M
N
P
200 cm/78" in front
30 cm/11.8" on left
60 cm/23.6" on right
30 cm/11.8" from back wall
60 cm/23.6" a
bove
Fig. 6.8
6.2 Drain joint installation
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit.
(See Fig. 6.9)
1. Fit the rubber seal on the end of the drain joint where it will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan.
3. Rotate the drain joint 90° until it clicks in place and faces the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit
during heating mode.
C
Note:
Make sure the water drains to a safe location where it will not cause water damage
or a slipping hazard.
6