23 / 116 EN
Split Type Air Conditioner / User Manual
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
Indoor unit
outline
302mm (11.88in)
36mm
(1.4in)
36mm
(1.4in)
47mm
(1.85in)
47mm
(1.85in)
Model C
285mm(11.2in)
243mm(9.57in)
45mm(1.7in) 240mm(9.5in)
143mm(5.6in)
100mm(3.9in)
958.3mm(37.7in)
458mm(18in)
Model D
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
324.9mm (12.79in)
55mm
(2.16in)
47mm
(1.85in)
47mm
(1.85in)
55mm
(2.16in)
264mm(10.4in)
1037.6mm(40.85in)
219mm(8.6in)
344mm(13.5in)
299mm(11.8in)
45mm(1.77in)
45mm(1.77in)
559mm(22in)
C
When the gas side connective
pipe is 16mm(5/8in) or more,
the wall hole should be 90mm
(3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating
sleeve attached to the back of the unit. You must
prepare the piping before passing it through the
hole in the wall.
1. Based on the position of the wall hole relative to
the mounting plate, choose the side from which
the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit. This
will create a slot through which your piping
can exit the unit. Use needle nose pliers if the
plastic panel is too difficult to remove by hand.
Knock-out Panel
Knock-out Panel
3. If existing connective piping is already
embedded in the wall, proceed directly to
the Connect Drain Hose step. If there is no
embedded piping, connect the indoor unit’s
refrigerant piping to the connective piping that
will join the indoor and outdoor units. Refer to
the Refrigerant Piping Connection section of
this manual for detailed instructions.
C
Refrigerant piping can exit the
indoor unit from four different
angles: Left-hand side, Right-
hand side, Left rear, Right rear.
A
CAUTION!
Be extremely careful
not to dent or damage the
piping while bending them
away from the unit. Any dents in
the piping will affect the unit’s
performance.
Step 5: Connect drain hose
By default, the drain hose is attached to the
lefthand side of unit (when you’re facing the back
of the unit). However, it can also be attached to
the right-hand side. To ensure proper drainage,
attach the drain hose on the same side that your
refrigerant piping exits the unit. Attach drain hose
extension (purchased separately) to the end of
4 Installation