6
•
The connection cable must not be
clamped,bent or trapped or come into
contact with hot parts of the oven. You
may cause the oven to short circuit and
catch fire as a result of the cable melting.
If the power cord is damaged, it must
be replaced by a qualified electrician.
Otherwise there is a risk of electric shock,
short circuit or fire!
•
The plug of the power cord should be
easily accessible after installation (but not
over the hobs).
•
When wiring, you must comply with
national / local electrical regulations and
use socket outlet / line and plug suitable for
the Oven. If the power limits of the product
exceed the current carrying capacity of
the plug and socket outlet / line, you must
connect the product directly to the fixed
electrical installation without using the plug
and socket outlet / line.
•
Make sure that fuse rating is compatible
with the product.
•
Connection must comply with national
regulations.
•
The mains supply data must correspond
to the data specified on the type label of
the product. Open the front door to see the
type label.
•
Power cable of your product must comply
with the values in “Technical specifications”
table.
•
If the product will be connected directly
to the supply power:
If it is not possible
to disconnect all poles in the supply
power, a disconnection unit with at least 3
mm contact clearance (fuses, line safety
switches, contactors) must be connected
and all the poles of this disconnection
unit must be adjacent to (not above) the
product in accordance with IEE directives.
Failure to obey this instruction may cause
operational problems and invalidate the
product warranty.
•
Additional protection by a residual current
circuit breaker is recommended.
If the product is produced with cable
and plug
•
Your product is produced with mains
cable and plug. Connect the plug of your
product to a grounded outlet and make the
electrical connection.
If the product is produced with cable
and without plug
•
Connect the cord of product to supply
power as identified below:
- Brown/black cable = L (Phase)
- Blue cable = N (Neutral)
- Green/yellow cable = (E)
(Ground)
If the product is produced without
cable and plug
A power cable that it is defined in the
technical table home must be connected to
product by following the instructions. Power
cable must not be longer than 2 m because
of safety reasons.
•
Open the terminal block cover with a
screwdriver.
•
Insert the power cable through the cable
clamp below the terminal and secure it to
the main body with the integrated screw on
cable clamping component.
•
Connect the cables according to the
supplied diagram.
- N = Neutral (Blue)
- L = Live-Phase (Brown/black)
- E = Ground
(Green/yellow)
- C =Cable clamp
•
After completing the wire connections,
close the terminal block cover.
•
Connect the power cable to supply power
by routing it so that it will not contact the
product and get squeezed between the
product and the wall.
Prevention against possible fire risk!;
•
Ensure all electrical connections are secure
and tight to prevent risk of arcing.
•
Do not use damaged cables or extension
cables.