20 / 28 EN
Mobile type air conditioners (local air conditioners) / User Manual
Fig. 16a
Fig. 16b
Fig. 17
Exhaust hose
Exhaust hose
Exhaust hose assembly
Exhaust hose assembly
Unit adaptor
Unit adaptor
Window slider adaptor
Wall exhaust adaptor A
Hook
Hole Seat
Type window installation
Type wall window installation
Lower groove
Adaptor
Make sure the
adaptor is inserted
into the lower
groove of the air
outlet.
Fig. 18
Fig. 19
max 120CM
Adaptor A
Adaptor
cap
min 30CM
Expansion plug
position
8.1 Exhaust hose installation
The exhaust hose and adaptor must be installed or removed in
accordance with the usage mode.
COOL, HEAT (heat pump type) or AUTO
mode
Install
FAN, DEHUMIDIIFY or HEAT (electrical
heat type) mode
Remove
1. Install the adaptor B and adaptor I onto the exhaust hose as
shown in Fig. 16a or Fig. 16b. Refer to the previous pages for
window kit installation.
2. Resert the hook of the Exhaust hose into the hole seat of
the air outlet and slide down the Exhaust hose along the
arrow direction (See Fig. 17) for installation.
The exhaust hose can be installed into the wall
(Not applicable to the units without adaptor A, expansion plugs
and wooden screws of Accessories).
1. Prepare a hole in the wall. Install the wall Exhaust adaptor
A onto the wall (outside) by using 4 expansion plugs and
wooden screws, be sure to fix thoroughly. (See Fig. 18)
2. Attach the Exhaust hose to wall Exhaust adaptor A.
C
Note: Cover the hole using the adaptor
cap when not in use.
• The exhaust hose can be compressed or
extended moderately according to the
installation requirement, but it is desirable to
keep the hose length to a minimum.
Important:
Do not over bend the exhaust hose (See Fig. 19)
A
Warning:
Make sure that there is no obstacle
around the air outlet of the exhaust
hose (in the range of 500mm) in order
to the exhaust system works properly.
8
Installation instructions