Inspection and maintenance

 

Service-Unit BEKOMAT® 31U / 31U F 

7

 

Pos : 20 /Beko T ec hnis che D okument ati on/Übersc hriften/ 1/ Kontr olle und Wart ung @ 0\ mod_1183637885371_2901. doc x @  5439 @ 1 @ 1 

 

Inspection and maintenance 

Pos : 21 /Beko T ec hnis che D okument ati on/Sic her hei t/G ef ahr Druc kl uf t @  0\ mod_1184148143854_2901. doc x  @  5778 @   @  1 

 

 

Danger! 

Compressed air! 

Risk of serious injury or death through contact with quickly or suddenly escaping 
compressed air or through bursting plant components or plant components which are 
not secured. 

 

Pos : 22 /Beko T ec hnis che D okument ati on/Sic her hei t/Maßnahmen Druc kluft BM @  0\ mod_1184148284291_2901. doc x  @  5814 @   @  1 

 

Measures: 

• 

Do not exceed the maximum operating pressure (see type plate).  

• 

Only carry out service measures  when the system is pressureless. 

• 

Use pressure-resistant installation material only. 

• 

The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant 
pipe.  

• 

Make sure that persons or objects cannot be hit by condensate or escaping compressed air. 

 

Pos : 23 /Beko T ec hnis che D okument ati on/Sic her hei t/G ef ahr Netzs pannung 1 s/ w @  0\ mod_1184148186948_2901.doc x @  5796  @   @  1 

 

 

Danger! 

Supply voltage! 

There is the risk of an electric shock involving injury or death when coming into contact 
with non-insulated components carrying supply voltage. 

 

Pos : 24 /Beko T ec hnis che D okument ati on/Sic her hei t/Maßnahmen N etzs pannung BM 31U/ 32U/ 33U  @ 7\ mod_1390467197804_2901. doc x @  38043  @   @  1 

 

Measures: 

• 

During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364). 

• 

When the control unit is open, service and installation works must only be undertaken when the 
system is deactivated.

 

• 

The removed control unit has no IP degree of protection. 

 

• 

All types of electrical works must be carried out by authorised and qualified personnel only. 

 

Pos : 25 /Beko T ec hnis che D okument ati on/Sic her hei t/Vorsic ht F ehlfunktion @  0\ mod_1214378096290_2901. doc x  @  9360 @   @  1 

 

 

Caution! 

Malfunction during operation! 

Through incorrect installation and poor maintenance, malfunction may occur at the 
BEKOMAT

®

 .  

Condensate which is not discharged may cause damage to plants and in production 
processes. 

 

Pos : 26 /Beko T ec hnis che D okument ati on/Sic her hei t/Maßnahmen F ehl funkti onen BM @  0\mod_1214378434025_2901. doc x @  9379 @   @  1 

Measures: 

• 

Condensate drainage which is reliable in performance directly optimises the compressed-air quality. 

• 

To prevent damage and breakdowns, it is imperative to observe the following: 

• 

Exact compliance with the specifications of use and with the performance parameters of  
the BEKOMAT

®

, in connection with the case of application (see "Proper use" section) 

• 

Exact compliance with the installation- and operation instructions in this manual

 

• 

Regular maintenance and control of the BEKOMAT

®

 in accordance with the instructions in this 

operating manual

 

 

Pos : 27 /Beko T ec hnis che D okument ati on/Sic her hei t/Hinweis Vorschrif ten Wer kzeug R einigung Kondensat Entsorgung @  0\ mod_1233239666823_2901. doc x @ 13340 @  @ 1 

 

 

 

Summary of Contents for BEKOMAT SUBM31U

Page 1: ...EN english Instructions for installation and operation Replacement unit Service Unit BEKOMAT 31U 31U F SUBM31U SUBM31UF 01 1610 ...

Page 2: ...2 Service Unit BEKOMAT 31U 31U F ...

Page 3: ...Service Unit BEKOMAT 31U 31U F 3 1 Pictograms and symbols 4 2 Safety instructions 4 3 Technical data 6 4 Inspection and maintenance 7 5 Elements and components 10 6 Recommended spare parts 11 ...

Page 4: ...ce Therefore it is imperative for the service technician and the responsible operator technical staff to read these operating instructions prior to installation start up and maintenance The operating instructions must be accessible at any time at the place of application of the BEKOMAT 31U In addition to these operating instructions local or national regulations must be complied with if necessary ...

Page 5: ...t drainage Use genuine spare parts only This is imperative to ensure perfect functioning Pos 13 Beko Technische D okumentati on Sicher hei t Zusatz Sicherheitshi nweise BM31 32 SA 31U 32U SA 0 mod_1185351496993_2901 docx 6480 1 Additional advice The removed control unit has no IP degree of protection During installation use spanner flat at the feed pipe wrenchsize SW27 as a back rest The service u...

Page 6: ...Leistg 5 mod_1358843578945_2901 docx 30450 1 min max operating pressure see type plate 0 8 16 bar 12 230 psi or 1 2 16 bar 17 230 psi min max temperature see type plate 1 60 C 34 140 F or 1 70 C 34 158 F Condensate inflow G NPT internal max screw in depth 13 5 mm Condensate outflow G Ø 8 10 mm hose connector Condensate oil contaminated oil free Housing aluminium plastic glass fibre reinforced Weig...

Page 7: ...31U 32U 33U 7 mod_1390467197804_2901 docx 38043 1 Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 When the control unit is open service and installation works must only be undertaken when the system is deactivated The removed control unit has no IP degree of protection All types of electrical works must be carried out by authorised and q...

Page 8: ...efore skin contact should be avoided Condensate is subject to mandatory waste disposal As such it must be collected in suitable containers and disposed of or processed properly Pos 28 Beko Technische D okumentati on Wartung BEKOM AT Wartung BM 31U 32U Ser vice Uni t 5 mod_1358510276825_2901 docx 30412 1 1 Prior to the replacement of the service unit a reset needs to be carried out The control unit...

Page 9: ...ignation and colour of the arresting hook 2 Check whether or not the sealing mat 11 or the sensor tube plate 14 with contact springs 13 are clean dry and free from impurities 3 Introduce the sensor 12 into the sensor tube plate 14 4 Hang the hook 15 of the control unit 1 in the sensor tube plate 14 5 Press the control unit 1 against the service unit 5 and snap into place Start up subsequent to mai...

Page 10: ...31U Ser vice U nit 6 mod_1378727822822_2901 docx 33608 1 1 Screw 3 5 x 10 2 Upper part of the cover 3 Moulded gasket 4 Printed circuit board 5 Sensor 6 Lower part of the cover 7 Cable bushing 8 Sealing mat 9 Service unit 10 Hose connector G 11 O ring 20 x 2 12 Intermediate adapter 13 Screw M6 x 12 14 O ring 14 x 1 78 15 Angle adapter 16 Design shell 17 Cord packing only previous version Pos 32 Sei...

Page 11: ...or BM31 or BM31BI Service Unit SUBM31UF for BM31UF or BM31UBIF or BM31UIFBIF or BM31F or BM31BIF or BM31IFBIF 8 9 11 4023607 4023608 Gasket kit 3 8 11 17 4024386 Design shell 16 4010164 Connection adapter 11 12 13 14 15 4010155 Not for BEKOMAT 31U built in or BEKOMAT 31U built in F Pos 35 Beko Technische D okumentati on Globale Texte Hinweis Ü bersetzg d Orig anl eitg 1 mod_1260433478358_2901 docx...

Reviews: