55 / 184 EN
Split Type Air Conditioner / User Manual
BEHPI
Model name
Indoor unit
BEHPI 090
BEHPI 120
BEHPI 180
BEHPI 240
Outdoor unit
BEHPI 091
BEHPI 121
BEHPI 181
BEHPI 241
Refrigerant
R32
R32
R32
R32
Total Refrigerant Amount (g)
550
550
1100
1450
GWP
675
675
675
675
CO2 equivalent (tonnes)
Anti-Electric
Class I
Class I
Class I
Class I
Climate Class
T1
T1
T1
T1
Heating Type
Heat Pump
Heat Pump
Heat Pump
Heat Pump
Power Supply Connection
Outdoor
Outdoor
Outdoor
Outdoor
2.7
3.5
5.2
7.0
2.7 (EU Average
Season)
2.9 (EU Average
Season)
4.1 (EU Average
Season)
4.9 (EU Average
Season)
SEER/AEER/Weight EER (W/W)
6.9 (SEER, EU)
7.0 (SEER, EU)
7.0 (SEER, EU)
6.5 (SEER, EU)
SCOP/ACOP/Weight EER (W/W)
4.0 (SCOP, EU
Average)
4.0 (SCOP, EU
Average)
4.0 (SCOP, EU
Average)
4.0 (SCOP, EU
Average)
Energy Level-Cooling
A++ (EU)
A++ (EU)
A++ (EU)
A++ (EU)
Energy Level-Heating
A+ (EU Average
Season)
A+ (EU Average
Season)
A+ (EU Average
Season)
A+ (EU Average
Season)
137
175
260
377
945
990
1435
1730
The declared capacity for calculation of SCOP
at reference design condition (kW)
2.63
2.69
3.39
3.69
The back up heating capacity assumed for
calculation of SCOP at reference design
condition (kW)
0.07
0.21
0.71
1.21
Power of Electric Heater (W)
/
/
/
/
Cooling Power Input (W)
/
/
/
/
Heating Power Input (W)
/
/
/
/
Voltage/Frequency (V/Hz)
220-240V~
50Hz, 1Ph
220-240V~
50Hz, 1Ph
Cooling Running Current (A)
/
/
/
/
Heating Running Current (A)
/
/
/
/
13 Specifications
Pdesign C (kW)
Pdesign H (kW)
0.371
0.371
0.743
0.979
Annual Energy Consumption-Cooling (kWh)
Annual Energy Consumption-Heating (kWh)
220-240V~
50Hz, 1Ph
220-240V~
50Hz, 1Ph