Initial safety checks shall include: that capacitors are discharged: this
shall be done in a safe manner to avoid possibility of sparking; that
there no live electrical components and wiring are exposed while
charging, recovering or purging the system; that there is continuity
of earth bonding.
2. Repairs to sealed components
2.1 During repairs to sealed components, all electrical supplies shall
be disconnected from the equipment being worked upon prior
to any removal of sealed covers, etc. If it is absolutely necessary
to have an electrical supply to equipment during servicing, then
a permanently operating form of leak detection shall be located
at the most critical point to warn of a potentially hazardous
situation.
2.2 Particular attention shall be paid to the following to ensure that
by working on electrical components, the casing is not altered
in such a way that the level of protection is affected. This shall
include damage to cables, excessive number of connections,
terminals not made to original specification, damage to seals,
incorrect fitting of glands, etc. Ensure that apparatus is
mounted securely. Ensure that seals or sealing materials have
not degraded such that they no longer serve the purpose of
preventing the ingress of flammable atmospheres. Replacement
parts shall be in accordance with the manufacturer’s
specifications.
1
Safety awareness
Summary of Contents for 1137254
Page 1: ...Portable Air conditioner User Manual EN FR IT NL BP109C BP112C BP112H BP113H BP109AC BP109AH ...
Page 54: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey ...
Page 109: ...Fabriqué par Arcelik A S Karaağaç Cd N 2 6 Sütlüce 34445 Beyoğlu Istanbul Turquie ...
Page 164: ...Prodotto da Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turchia ...
Page 219: ...Geproduceerd door Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanboel Turkije ...
Page 220: ...www beko com ...