Connecting With The Mains
The machine is equipped with a drive motor driving by a v -belt and other necessary electrical equipments. Electrical box is
installed on the lower part. Control panel is mounted on the electrical box. The machine is connected with the mains at the electrical box.
R, s
and
t
stand for phases,
n
stands for neuter and
pe
stands for ground.
Three-phase motors allow an easy change of the poles at the connecting flexes in order to correct the direction of cutting
Filling Of Coolant
Consisting of a mixture of liquid and water coolant liquid should be used for steel cutting. Coolant should not be used for
cutting casting. Specific periods of time (at least once a month) , coolant should be drained and clean chips. İf amount of coolant is not
enough, add to the tank. (4 liters of tank capacity. Collant mixing ratio 1/10)
Setting New Blade
·
First of all both guard flaps and the guards which are on the guide arms have to be open upwards.
·
Loosen the blade by the hand level so far that the blade can be easily taken off around the pulleys
·
The same way but vic averse, fit and tighten the new blade. There is also possibility to tighten the blade by torque meter.
·
Always pay attention to the teeth of the blade’s direction is correct. İf not correct it.
Cutting Speeds
The machine has two pre-selected cutting speeds of 20 and 100 m/sec. Cutting speeds has to be selected according to the grade
and dimensions of the material. İf any vibration and/or noise raises from the blade, change the speed.
·
All the details about the cutting of various materials and dimensions are given below