5.2

Controls when configured as a Timer

The BA577E-SS is controlled and configured via four
front panel push buttons.     In the display mode i.e.
when   the   instrument   is   displaying   time   the   push
button functions are:

Push Button Functions

&

When local control is enabled starts
the Timer.  See 5.5.8

*

When local control is enabled stops
the Timer.  See 5.5.8

)

 + 

*

Shows the grand total time in hours
and tenths of an hour irrespective of
Timer configuration.   If buttons are
held for longer than ten seconds the
grand total may be reset to zero if
the   grand   total   reset   sub-function

clr gtot

 is enabled in the 

LoC r5Et

configuration function.   See 5.5.20

To reset the grand total to zero from
the display mode press the          

)

+  

*

  buttons for ten seconds until

CLr. no

 is displayed, using the 

&

 or

*

 button change the display to 

CLr.

YE5

 and press 

)

.

&

 + 

*

 

Resets the Timer to zero or to the
set   time  

5Et   t

  depending   on

whether the Timer is configured to

time-up

  or 

time-down

 when the two

buttons

 

are

 

operated

simultaneously for more than three
seconds.     This   is   a   configurable
function.  See 5.5.19

(

 + 

*

When   enabled   in   the   configuration
menu, operating these two buttons
simultaneously   provides   direct
access   to   the   set   time  

5Et   t

  and

allows adjustment when the timer is
in the display mode.  See 5.5.15

(

 + 

&

Shows   in   succession,   firmware
version number, instrument function

elap5e

  and any output accessories

that are fitted:

-A 

    Dual Control Outputs

(

 + 

)

Access to configuration menu

5.3

Displays when configured as a Timer

The   BA577E-SS   has   two   digital   displays   and
associated annunciators as shown on front cover of
this manual.

Elapsed time

The   upper   display   shows   the
elapsed   time   since   the   Timer
was started when 

timing-up 

from

zero  and   the   remaining   time
when  

timing-down

  from   the   set

time.       The   display   may   be
formatted as  hh:mm:ss; hh:mm;
mm:ss or ss. 

Lower display

The display options available on
the   lower   display   depend   on
whether   the   Timer   repeat   cycle
function  

CYCLE5

,   which   can

repeat the timing period up to 99
times,   or   continuously   with   a
configurable   delay   between
periods, is enabled.

CYCLE5

 disabled

The lower display shows the set
time  

5ET t

,  or the lower display

may be disabled if not required.
See 5.5.7

CYCLE5

 enabled

The   lower   display   shows   the
total   number   of   repeat   cycles
requested   together   with   the
number   of   the   current   cycle.
Each   operation   may   be   briefly
named at it's start or periodically
throughout the cycle.
The   lower   display   may   also   be
disabled if not required.
See 5.5.7

Reset

Activated  while  elapsed  time is

annunciator

being reset to zero or to the set
time 

5ET t

.

Grand total

Activated  when  the  grand  total

annunciator

time is being shown on the upper
display.

Control output

Show  status   of   both   optional

annunciators

control outputs.

Summary of Contents for BA577E-SS

Page 1: ...Issue 6 4th May 2021 BA577E SS Rugged one input general purpose Timer or Clock Issue 6...

Page 2: ...t 5 5 11 Repeat timing cycle CYCLE5 5 5 12 Cycle function enable EnbL 5 5 13 Cycle count cycl cnt 5 5 14 Restart delay r5t dela 5 5 15 Adjusting the set time 5Et t and restart delay r5t dela from the...

Page 3: ...4 8 Enable Control output 1 EnbL 8 4 9 On and off times oP 1 on 1 oP 1 off 1 oP 1 on 2 oP 1 off 2 8 4 10 Control output 2 Optional oP2 8 4 11 Enable control output 2 EnbL 8 4 12 On and off times oP2...

Page 4: ...circuit that is used for all BA577E SS Timer installations Clock installations are the same except that the input terminals 5 6 are not used For simplicity the optional control outputs are described s...

Page 5: ...etic pick off sensor which is not suitable for controlling the BA577E SS 2 2 5 Voltage input Two voltage input ranges are independently selectable in the BA577E SS Timer configuration menu VoLt5 L and...

Page 6: ...BEKA stainless steel support plate should be slid over the rear of the Counter before the panel clamps are fitted to evenly distribute the clamping force and prevent the enclosure panel being distort...

Page 7: ...g the requested units of measurement if this information is not supplied when the instrument is ordered a blank card will be fitted A pack of self adhesive scale cards printed with common units of flo...

Page 8: ...isplay through which a scale card showing the units of time such as hours can be seen New instruments are fitted with a scale card showing the units of measurement specified when the instrument was or...

Page 9: ...ished via the front panel push buttons or by a remote contact A grand total time is maintained which can be viewed by operating the front panel push buttons It may be reset to zero from within the con...

Page 10: ...5 Shows in succession firmware version number instrument function elap5e and any output accessories that are fitted A Dual Control Outputs Access to configuration menu 5 3 Displays when configured as...

Page 11: ...d of the delay time automatically returns to Running Complete Entered automatically from Running when there are no more timing cycles to perform When the CYCLE5 function is enabled the timing cycle ca...

Page 12: ...he instrument using the or push button to adjust the flashing digit and the push button to transfer control to the next digit If the correct code has been entered pressing will cause the first paramet...

Page 13: ...itch contact Energise input by linking terminals 3 4 See section 5 5 5 dEbounCE Defines the level of debounce applied to the input to prevent false functioning dEFAuLt HEAVY LiGHt See section 5 5 6 Di...

Page 14: ...e display mode to 5Et t and r5t dela See section 5 5 15 Display Summary of function uP or dn Direction of count Defines whether the Timer times down from 5Et t to zero or times up from zero to the set...

Page 15: ...control output 1 See section 5 5 26 Display Summary of function CLr Gtot Resets grand total to zero This function resets the grand total which represents the total Timer run time from within the conf...

Page 16: ...s required press twice to return to the configuration menu or repeatedly press the or button until the required type of input is displayed and then press twice to return to the configuration menu One...

Page 17: ...n at start of each period 02 11 Current Number of cycles cycle requested not shown number when cycle is continuously repeated LabEL Exactly the same as 5td but timer status i e CYCLE or dELAY is shown...

Page 18: ...18...

Page 19: ...19...

Page 20: ...l to the next digit When set as required enter the selection and return to the cycl cnt prompt in the sub menu by operating the button 5 5 14 Restart delay r5t dela This sub function defines the time...

Page 21: ...mediately Continue When power is restored the Timer will continue from where it stopped without any manual intervention To check or change the function select P fail from the configuration menu and pr...

Page 22: ...uration example in section 6 2 of this manual illustrates the use of the control outputs Further examples can be found in Application Guide AG374 which is available on the BEKA website 5 5 22 Control...

Page 23: ...it can be adjusted using the or button and the button to move to the next digit When the required delay has been entered press to return to the control output 1 sub menu The Timer configuration exampl...

Page 24: ...rol to the second digit which should be set to u When 5urE has been entered pressing the button will reset all the configuration functions and return the instrument to the display mode Note r5Et dEF d...

Page 25: ...he required instrument configuration for this example are shown below Function Display Setting Access code CodE 0000 Function FunCtion ELAP5E Input inP type ContACt debounce dEbounCE dEFAuLt Display 2...

Page 26: ...r configuration menu Incorrect security code That the correct security code is being used Contact BEKA if code is lost 7 2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTEN...

Page 27: ...e regularly checked Inspection frequency should be chosen to suit the environmental conditions 7 5 Guarantee Instruments which fail within the guarantee period should be returned to BEKA associates or...

Page 28: ...rument s permanent memory Following initialisation the instrument will display a flashing display which is a request for the local time to be entered The clock will not start to function until a displ...

Page 29: ...hroughout this manual push buttons are shown as and and legends displayed by the Clock are shown in a seven segment font as they appear on the instrument e g di5PLAY and CodE Access to the configurati...

Page 30: ...30...

Page 31: ...ntrol output 1 Optional Control output 1 can turn on output closed and off output open twice in each twenty four hour period This function contains five sub function EnbL Enables output 1 and defines...

Page 32: ...et time is entered the Clock will display a flashing 00 00 00 or 00 00 for 24 hour formats or A12 00 00 or A12 00 for 12 hour formats To adjust the clock set time select 5Et from the configuration men...

Page 33: ...tered return to the configuration menu by pressing the button twice 8 4 10 Control output 2 Optional oP2 Control output 2 is an optional factory fitted output which can be configured to turn on output...

Page 34: ...e display mode may be protected by a four digit alphanumeric security code which must be entered to gain access Default security code 0000 allows unrestricted access With ACCd displayed press to enter...

Page 35: ...g will then change the instrument to a Clock and return the display to FunCtion in the configuration menu Step 3 Select display format Using the or button select di5PLAY in the configuration menu and...

Page 36: ...access to the configuration menu Using the and buttons select CodE from the configuration menu and press which will reveal 0000 with the first digit flashing This example requires the security code to...

Page 37: ...ANCE If a BA577E SS fails after it has been functioning correctly as a Clock the following table may help to identify the cause of the failure Symptom Cause Check No display No power supply That there...

Page 38: ...8 10 6 Customer comments BEKA is always pleased to receive comments from customers about our products and services All communications are acknowledged and whenever possible suggestions are implemented...

Reviews: