3.2.5 Magnetic pick-off input
Sensors incorporating a magnetic pick-off will usually
have a low level ac voltage output which a BA564G
Counter can sense when configured for a
CoiL
input.
The BA564G contains a configurable debounce circuit
to prevent false triggering. See sections 5.6 and 5.9.
3.2.6 Voltage pulse input
Two voltage pulse input ranges are selectable in the
BA564G Counters configuration menu,
VoLt5 L
and
VoLt5 H
. The BA564G contains a configurable
debounce circuit to prevent false triggering. See
sections 5.6 and 5.9.
3.3 Remote reset
The BA564G Counter's total display may be
remotely reset by connecting terminals RS1 and
RS2 together. Permanent interconnection inhibits
counting. Remote resetting may be accomplished
by any switch contact.
The BA564G total display may also be reset when
the
&
and
*
push buttons are operated
simultaneously in the operating mode i.e. when the
instrument is counting. See 5.24