6.5.7 Batch Limit
To prevent accidental over-filling, the Batch
Limit defines the maximum batch that may be
dispensed. If a batch setpoint greater than the
Batch Limit is entered, it will be accepted but a
warning will appear on the screen. The
position of the decimal point will be the same
as the batch display. See 6.5.5.
99999999
Set Batch Limit
6.5.8 Batch Names
This function enables up to nine pre-entered
batch setpoints to be identified with individual
names each having up to sixteen alphanumeric
characters. The name is displayed when the
Batch Size setpoint is selected or adjusted see
sections 6.5.9 and 6.5.10. Some of the
operator display screens also show the
setpoint name.
Batch 1
Set Batch Names
6.5.9 Batch Size
The named batch setpoints can be assigned a
value with this function. The position of the
decimal point in all the setpoints will be as
defined by the Batch D.P. function. - See 6.5.5.
Batch 1
Batch 2
To
Batch 9
00000000.
Set Batch Size
Note:
May be included in Operator Menu.
See 2.1
6.5.10 Select Batch
This allows the batch controller’s operating
setpoint to be selected from the nine pre-
entered setpoints. To select, highlight the
name of the required setpoint and press
E.
The setpoint value will be shown at the bottom
of the display screen.
Batch 1
Batch 2
To
Batch 9
XXXXXXXX
Select Batch
Note:
May be included in Operator Menu.
See 2.1
6.5.11 Batch History
The volume of product dispensed in the
previous nine batches is recorded by this
function.
Batch n: XXXXXXX
n-1:
n-2:
to
n-9:
Batch History
Note:
May be included in Operator Menu.
See 2.1
6.5.12 CONTROL2delay
(Control 2 Start Delay)
At the start of a batch, Control 1 is energised
immediately the
Start
button is operated.
Control 2 may be energised at the same time,
or delayed for up to 3600 seconds by this
function.
0000
CTL2 Delay: Seconds
27
Summary of Contents for BA454D
Page 1: ...Issue 12 29th August 2014 BA454D Intrinsically safe Field mounting Batch Controller Issue 12 ...
Page 14: ...Fig 10 Dimensions and terminal connections 14 ...
Page 17: ...17 BLANK PAGE ...
Page 18: ...18 Fig 11 System Settings Fig 11 System Settings ...
Page 23: ...23 BLANK PAGE ...
Page 24: ...24 Fig 14 Batch Settings ...
Page 29: ...29 BLANK PAGE ...
Page 30: ...30 Fig 16 Rate Settings ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...Appendix 2 Information menu 40 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ...48 ...
Page 49: ...49 ...