55
3.5.10 Continue cycle: ‘ContinuE’
This function determines how the timer operates
when power is restored after an interruption.
Two options are available.
‘OP.OFF’
When power is restored, after initialisation, the
instrument will show the display(s) present
when power was removed. The timer will then
wait for a starting instruction. Both optional
control outputs will be open.
‘OP.rEStOr’
When power is restored, after initialisation, the
instrument will show the display(s) present
when power was removed. The timer will then
wait for a starting instruction. Both optional
control outputs will be restored to their condition
when power was removed.
To check or change the status of this function
select 'ContinuE' from the main menu and press
P
which will reveal the current setting. Pressing the
Up
or
Down
buttons will toggle the display between
‘On’ and ‘OFF’. When set as required, press the
E
button to enter the setting and return to the main
menu.
3.5.11 Local reset of timer: ‘LOC- rSEt’
When local reset is turned on, operating the
Up
and
Down
push-buttons simultaneously for more
than two seconds in the display mode will reset the
timer.
To check the status of the local reset function
select 'LOC-rSEt' from the menu and press
P
which will reveal if the function is 'On' or 'OFF'. If
required press the
Up
or
Down
button to change
the setting, followed by the
E
button to return to the
main menu.
The timer may also be reset remotely by
connecting terminals 7 and 8 together.
3.5.12 Resetting elapsed time grand total:
‘CLr. Gtot’
The grand total is a separate eight digit counter
which totalises elapsed time in hours and tenths of
an hour, but is not cleared when the timer is reset.
The grand total time may be viewed when the
instrument is in the display mode by operating the
E
and
Down
push-buttons simultaneously.
The grand total time can only be reset to zero from
the 'CLr. Gtot' function in the main programme
menu. To zero the grand total select 'CLr. Gtot'
and press
P
which will cause the instrument to
display 'Clr. no' with 'no' flashing. Continuously
press the
Up
or
Down
push-buttons until 'CLr. YES'
is displayed and then press
P
which will result in a
'CLr. 0000' prompt with one digit flashing. Using
the
Up
, and
Down
buttons and the
P
button to
move to the next digit, confirm the request by
entering the password 'SurE'. Note 'S' is entered
as '5'. Pressing
E
will then reset the grand total
counter to zero and return the instrument to the
'CLr. Gtot' prompt in the main menu.
WARNING
After resetting the grand total to
zero the old grand total can not be
recovered.
3.5.13 Security code: ‘CodE’
The calibration and conditioning of the BA368C
may be protected by a four digit security code
which must be entered before access to the
programme menu is allowed. New instruments
are programmed with the default security code
0000 that allows unrestricted access to all
programming functions without entering a security
code.
To enter a new security code select 'COdE' from
the menu and press
P
which will cause the
instrument to display the current security code.
Each digit of the code can be changed using the
Up
and
Down
push-buttons, and the
P
button to
move to the next digit. When the required code
has been entered press
E
to return to the main
menu. The revised security code will be activated
when the instrument is returned to the display
mode.
If the security code is lost, access to the
programmable functions can be obtained by
moving the internal security link to the override
position as shown in section 1.6.1. The original
security code can then be viewed by selecting
'COdE' from the main menu and pressing
P
.
Summary of Contents for BA368C
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 18: ...18 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 28: ...28 ...
Page 34: ...34 ...
Page 44: ...44 ...
Page 52: ...52 ...
Page 67: ...67 ...
Page 72: ...72 ...
Page 80: ...80 ...
Page 87: ...87 ...