50
APPENDIX 3
ETL & cETL certification for installations in USA
and Canada.
A3.0 cETL Mark
For installations in the USA and Canada, the
BA334G Rate Totaliser has ETL and cETL intrinsic
safety and nonincendive approval, Control Number
4008610. Copies of the Authorisation to Mark may
be downloaded from the BEKA associates website
www.beka.co.uk
or requested from the BEKA
associates sales office
A3.1 Intrinsic safety approval
The US and Canadian standards used for
assessment and certification of the BA334G are
listed on the cETL Authorisation to Mark.
Installations must comply with BEKA associates
Control Drawing CI330-52, which is attached to this
appendix.
The ETL safety parameters are the same as the
ATEX and IECEx parameters, the systems shown in
sections 3 and 4 of this manual may therefore also
be used for US and Canadian installations subject to
compliance with the local codes of practice.
ETL and cETL intrinsic safety codes
USA & Canada
CL I Div 1 Groups A, B, C, D T5
CL II Div 1 Groups E, F, G. CL III
-40ºC < Ta < 70ºC
USA
CL I Zone 0 AEx ia IIC T5 Ga
Zone 20 AEx ia IIIC T80ºC Da
-40ºC < Ta < 70ºC
Canada
Ex ia IIC T5 Ga
Ex ia IIIC T80ºC Da
-40ºC < Ta < 70ºC
A3.2 Nonincendive approval
The BA334G Rate Totaliser also has ETL
nonincendive approval allowing installation in
Division 2 hazardous (classified) locations without
the need for Zener barriers or galvanic isolators.
Installations must comply with BEKA associates
Control Drawing CI330-53, which is attached to
this appendix, and with the local codes of practice.
ETL and cETL nonincendive codes US &
Canada
CL I Div 2 Groups A, B, C, D T5
CL II Div 2 Groups F, G
CL III Div 2
-40ºC < Ta < 70ºC
Summary of Contents for BA334E
Page 22: ...22 ...
Page 23: ...23 ...
Page 32: ...32 ...
Page 43: ...43 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...
Page 55: ...55 ...
Page 56: ...56 ...
Page 57: ...57 ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 61: ...61 ...
Page 62: ...62 ...