7. ACCESSORIES
7.1 Scale card
The A90-SS panel meter has a window on the right
hand side of the display through which to view a
scale card showing the units of measurement such
as
o
C, mbar or rpm. New meters are fitted with a
scale card showing the units of measurement
specified when the meter was ordered, if the units
are not specified a blank scale card will be fitted.
A pack of scale cards pre-printed with common
units of measurement is available as an accessory.
These can easily be fitted to the A90-SS meter
without opening the instrument enclosure or
removing it from the panel, See section 4.4 of this
instruction manual.
Custom scale cards for applications requiring less
common units of measurement are also available.
7.2 Tag information
New meters can be supplied with tag or application
information printed onto the rear panel adjacent to
the terminals, This tag information is not visible
from the front of the instrument after installation.
7.3 Alarms
CAUTION
These alarm outputs should not be used for
critical safety applications such as an
emergency shut down system.
The A90-SS panel meter can be supplied with
factory fitted dual alarms each having a single pole
changeover relay contact output. Each alarm may
be independently conditioned as a high or low
alarm.
When the A90-SS panel meter power supply is
removed both alarm outputs will be de-energised.
This condition should be chosen as the alarm
condition when designing an alarm system.
When an alarm occurs an alarm annunciator on
the A90-SS front panel is activated and if required
the numerical display can alternate between the
measured value and the alarm channel
identification
ALr1
or
ALr2
.
CAUTION
The alarms are activated by the meter’s
numerical display. Use of the Tare Function
tArE
will change the numerical display, the
alarms will continue to function at the original
displayed value, but this will correspond to a
different input.
Configurable functions for each alarm include
adjustable setpoint, hysteresis, alarm delay and
alarm accept.
7.3.1 Alarm relay contacts
Each alarm has a single pole change over relay
output which as shown in Fig 10.
Fig 10 Alarm contact outputs
The contact rating are:
ac
250V 5A
dc
30V 5A
Inductive loads should be suppressed to ensure
that the relay contact ratings are not exceeded.
20