9
User manual
1.4 Installation
The unit should be mounted by its screws holes on the bracket. Always ensure that the unit is firmly fixed
to avoid vibration and slipping while operating. The structure to which you are attaching the unit should
be able to support 10 times the weight of the unit. Also always use a safety cable than can hold 12 times
the weight of the unti when installing the fixture. The equipment must be fixed by professionals
.
2.
TECHNICAL SPECIFICATIONS
- 200W LED
- 6000-6500K
- PHILIPS LEDS
- MEANWELL DRIVER
3.
MAINTENANCE AND MALFUNCTIONS
There is no specific maintenance needed, do not open the unit, it may change the IP rating; make sure
the radiator stays clean.
If there is a malfunction, these are the possible malfunctions:
-No light due to bad connection cable: change the cable
-The power input is bad: change the connector (must be done by qualified technician)
-The power supply is dead: change the power supply completely.
-One or all leds on the PCB is dead: change the PCB completely.
-Glass has been broken: change the glass
-All service must be done by a qualified technician. All service parts are available at:
Pro Audio Trade bvba
–
Heilig Hartstraat 23
–
8870 Izegem 00 32 51 31 28 03
–
Oefoled 200