6.4.2
Altering the global parameters
Parameter 45:
Number of stitches until the table blowing is switched
on
Input:
0 …200
Parameter 46:
Duration of the stacker impulse
Input:
0 ..2000
Parameter 47:
Time of stacker movement
Input:
0 …
Parameter 48:
Speed limitation
Input:
max. 8500
Parameter 49:
Speed at warp separation
Input:
0 …5000
Parameter 50:
Number of stitches until the thread tension
is opened (seam end)
Input:
0....50
Parameter 56:
Seam programming on/ off
On = Determine the seam sequences in the current
program
Off = Create the next free program with seams
Input:
0 and 1
Parameter 57:
Time how long the holding stamp is down
Input:
0 …2000
Parameter 58:
Display of the software version
Parameter 59:
Number of stitches how long the seam chain is
sucked (seam beginning)
Input:
0 ...150
Parameter 65:
Thread tension lift at the beginning
Input:
0 …
Parameter 66:
Fusing time
Input:
0 …
Parameter 67:
Time of the swivelling movement to the stacker
Input:
0 …
Parameter 68:
Time when the swivelling device swivels back
Input:
0 …
Parameter 80:
Reset the daily piece counter
27