To use your TS1008 digital tester for a long time, use it and store it with the following precautions in mind.
MAKE SURE of integrity after removing it from the box.
Any use other than that for which the detector was designed is to be considered improper, so the BEINAT S.r.l. declines
all responsibility for any damage caused to people, animals or things.
For your safety, in the event of a malfunction, switch off the appliance immediately.
If you notice smoke or an acrid or unusual smell coming from the appliance, switch off the instrument immediately and
send the appliance to the nearest Service center.
Use the appropriate cables supplied.
In order to preserve the conformity of the product with the regulations, for the connection to the input and / or output
terminals of the detector, use only cables supplied for this purpose or sold separately from BEINAT S.r.l.
Avoid contact with liquid crystals.
If the display breaks, be careful not to hurt yourself with the glass fragments and avoid the liquid crystals coming into
contact with the skin, eyes or mouth.
Do not wet it.
The detector is not waterproof if it is submerged in water or exposed to high humidity levels and can cause serious
damage.
Do not let it fall.
Strong blows against rigid surfaces and large vibrations can damage the appliance.
Avoid strong magnetic fields.
This detector should not be used or stored in the presence of radiation or strong magnetic fields. Static electricity or
magnetic fields produced by equipment such as radio transmitters can interfere with detection.
Cleaning
Never clean the appliance with chemicals. If necessary, wash with a damp cloth.
From the experience since 40 years and the requirements of the rules of the test, BEINAT Srl has built a new tool Tester
TS1008 for its own products.
Mainly this new device is suitable to test all conventional probes to detect explosive and toxic gas manufactured
by BEINAT Srl
This device allows to read all of the data and the configuration of work that are in the memory of the probes, also,
having supplied by the serial transmission, it prints the ticket that confirms the testing data, certifying your own
work.
By the Tester TS1008, you can read all of the events that occurred in the probe, such as:
1) The type of probe
2) The serial number of the probe.
3) The status of current work, WAITING (warm up) - READING DATA - FAULT - ALARM.
4) How many times the voltage has been On/Off.
5) How many times it issued an alarm.
6) The status of the current calibration.
7) How many times the correction has been made.
8) How many operating days remain before the substitution of the sensing element.
Page 2
Powered by Lithium Polymer battery ……………………........…...................................................... 3.7 V.cc built-in
Consumption during other detection...................................................................................................3 mA
Consumption during printing..............................................................................................................4 mA
Battery autonomy according to functions .............................................................................380 hour approx
Battery charging and consumption control....................................................................................On Display
Alphanumeric display ...........................................................................................................Alpha numeric
Storing Events ............................................................................... one until the instrument is switched off
Compatible sensors ................................
SGM595, SGM533, SG895, SG800, CO100r, HCF100, serie SGF, CXM200/Q
Auto power off................................................................................................... after 1 hour of stand-by
Operating temperature .................................................................................................. -10° C ÷ + 45° C
Working humidity not condensed ..........................................................................................from 0 to 90%
Printing ........................................................................................................................... With IR port
Electromagnetic Compatibility ......................................................................................................... CE
Dimensions and weight ..................................................................................... 65 * 135 *32mm circa 180gr
Attention!
All measurements taken with batteries in need of recharge can give false measurements.
Main features
Important warnings
Technical specifications
Thank you for choosing the digital tester of BEINAT S.r.l. mod. TS1008
This manual has been designed to help you achieve maximum functionality and automatic product efficiency.
Read these instructions carefully before beginning use and always keep it handy when using the instrument.
The illustrations and text on the screens shown in this manual may differ from what is actually displayed.