To use your TS1008 digital tester for a long time, use it and store it with the following precautions in mind.
MAKE SURE of integrity after removing it from the box.
Any use other than that for which the detector was designed is to be considered improper, so the BEINAT S.r.l. declines
all responsibility for any damage caused to people, animals or things.

For your safety, in the event of a malfunction, switch off the appliance immediately.
If you notice smoke or an acrid or unusual smell coming from the appliance, switch off the instrument immediately and
send the appliance to the nearest Service center.
Use the appropriate cables supplied.
In order to preserve the conformity of the product with the regulations, for the connection to the input and / or output
terminals of the detector, use only cables supplied for this purpose or sold separately from BEINAT S.r.l.
Avoid contact with liquid crystals.
If the display breaks, be careful not to hurt yourself with the glass fragments and avoid the liquid crystals coming into
contact with the skin, eyes or mouth.
Do not wet it.
The detector is not waterproof if it is submerged in water or exposed to high humidity levels and can cause serious
damage.
Do not let it fall.
Strong blows against rigid surfaces and large vibrations can damage the appliance.
Avoid strong magnetic fields.
This detector should not be used or stored in the presence of radiation or strong magnetic fields. Static electricity or
magnetic fields produced by equipment such as radio transmitters can interfere with detection.
Cleaning
Never clean the appliance with chemicals. If necessary, wash with a damp cloth.

From the experience since 40 years and the requirements of the rules of the test, BEINAT Srl has built a new tool Tester
TS1008 for its own products.
Mainly this new device is suitable to test all conventional probes to detect explosive and toxic gas manufactured
by BEINAT Srl
This device allows to read all of the data and the configuration of work that are in the memory of the probes, also,
having supplied by the serial transmission, it prints the ticket that confirms the testing data, certifying your own
work.

By the Tester TS1008, you can read all of the events that occurred in the probe, such as:

1) The type of probe
2) The serial number of the probe.
3) The status of current work, WAITING (warm up) - READING DATA - FAULT - ALARM.
4)
 How many times the voltage has been On/Off.
5) How many times it issued an alarm.
6) The status of the current calibration.
7) How many times the correction has been made.
8) How many operating days remain before the substitution of the sensing element.

Page 2

Powered  by  Lithium  Polymer battery  ……………………........…......................................................  3.7 V.cc  built-in
Consumption  during  other  detection...................................................................................................3  mA
Consumption  during  printing..............................................................................................................4  mA
Battery autonomy according to functions .............................................................................380 hour approx
Battery  charging  and consumption  control....................................................................................On  Display
Alphanumeric display  ...........................................................................................................Alpha numeric
Storing  Events  ...............................................................................  one  until  the  instrument  is  switched  off
Compatible  sensors    ................................   

SGM595,  SGM533,  SG895,  SG800, CO100r,  HCF100,  serie  SGF,  CXM200/Q

Auto  power  off...................................................................................................  after  1  hour  of  stand-by
Operating  temperature  ..................................................................................................  -10°  C  ÷  +  45°  C
Working  humidity  not condensed ..........................................................................................from  0 to 90%
Printing    ...........................................................................................................................  With  IR  port
Electromagnetic  Compatibility        .........................................................................................................  CE
Dimensions and weight   ..................................................................................... 65 * 135 *32mm  circa 180gr

Attention!

All measurements taken with batteries in need of recharge can give false measurements.

Main features

Important warnings

Technical specifications

Thank you for choosing the digital tester of BEINAT S.r.l. mod. TS1008
This manual has been designed to help you achieve maximum functionality and automatic product efficiency.
Read these instructions carefully before beginning use and always keep it handy when using the instrument.
The illustrations and text on the screens shown in this manual may differ from what is actually displayed.

Summary of Contents for TS1008-V1

Page 1: ... of the cycle Check and view how many times it has been turned on Check and view how many times it has detectedan Alarm Check and view how many corrections have been made Check and display the operating range of LEL Check and display the operation of the device Issues the receipt proving the operation TS1008 V1 Self certifying Tester for GAS Detectors and Sensors Certify the test by printing the r...

Page 2: ...s new device is suitable to test all conventional probes to detect explosive and toxic gas manufactured by BEINAT Srl This device allows to read all of the data and the configuration of work that are in the memory of the probes also having supplied by the serial transmission it prints the ticket that confirms the testing data certifying your own work By the Tester TS1008 you can read all of the ev...

Page 3: ...the 4 screws located at the back of the instrument 3 Raise the cohesion 4 Remove the batteries 5 Insert the new batteries positioning them in the correct direction 6 Replace the cover and tighten the 4 screws 7 Turn on the instrument and continue in your work Use Batteries must never be exposed to temperatures above 40 C To ensure optimal durability use them at room temperature If used at both low...

Page 4: ...on 6 Checking the status of the battery Pressing the UP and DOWN buttons at the same time the message BAT appears on the display followed by three segments Segments full charged battery empty segments empty battery DISPLAY The display used on the TESTER is of the alphanumeric type and is used to display the following information 3 LEL unit of measurement for explosive gas ppm for the toxic gas the...

Page 5: ...ctioning and is reserved for authorized technicians To see the next page press DOWN PAGE 2 to scroll the page press ENTER Displays the percentage of gas dispersed in the environment can be expressed in of LEL or in ppm In case of failure appears only FAULT Displays the type of gas for which the probe has been calibrated To see the next page press DOWN PAGE 3 PRINT to print point the IR transmitter...

Page 6: ...rged if it is not recharge it If the device does not detect Check that the cables are well plugged in and make contact If the device does not print Check that the instrument is in line with the printer Check that the printer is turned on and is in line with the instrument In the event other problems arise directly contact a specialist and or authorised technician or your BEINAT S r l dealer Proble...

Page 7: ...inder within the percentages described for each type of equipment Ordinary and extraordinary maintenance and putting out of service at the end of the operating period guaranteed by the manufacturer must be carried out by authorized and or specialized personnel LEL 20 Senso r Analyzer TS1008 Edit Enter UP Down Accessories To perform the test and to obtain a self certification it is necessary to use...

Page 8: ...nd from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment such as for example sales points in case you buy a new and similar product...