RD-EK32 Series User Development manual
9
4.2 Installation method
4.2.1 Operation
Please read following before the installation
1
、
The material thickness of the panel should be 0.8mm
~
4.5mm
2
、
The Printer is planarity structure, The panel need to be flat(not Cambered),The flatness
should be within 0.15mm.
3
、
When installing the printer, the fixed support should be screwed tight in case damage.
4.2.2 Installation operation
1
、
。
The instrument panel square hole size should be 80x80mm
2
、
Put the printer into the panel hole.
3
、
Tight the screw clockwise, The fixed support will be spread by two sides, Clamp the panel
4
、
When the screw is tight with resistance, it means the fixed support locked the panel, then
stop the tightening.
4.2.3 Unloading Operation
1
、
Rotate the screw counterclockwise, with the unscrew, the support will pack up inward
2
、
Back out the screw around 7mm,the support will withdraw into the printer completely, then
the printer can be taken out.