Chemical Resistance

5.1.2

Touch Screen Surface

The touch screen surface on the operator panel withstands exposure to the
following solvents without visible change:

Solvents

Time

Acetone

10 minutes

Isopropanol

10 minutes

Toluene

5 hours

The touch screen surface on the operator panel is made of polyester with a hard
coat to resist scratches and withstand exposure to many solvents without visible
change.

5.1.3

Touch Screen Protector

For harsh environments and exposure to outdoor conditions, it is recommended
to use a protective film to guard the touch screen from damage. This optional part
can be ordered from Beijer Electronics.

Beijer Electronics, MAEN329

14

Summary of Contents for X2 base 7 v2

Page 1: ...X2 base 7 v2 English MAEN329 2021 02...

Page 2: ...l its group companies assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only quali ed personnel...

Page 3: ...e Controller 9 3 2 2 Other Connections and Peripherals 10 3 2 3 Open Ports 10 4 TechnicalData 11 5 ChemicalResistance 13 5 1 Touch Screen and Overlay Material 13 5 1 1 Protective Film 13 5 1 2 Touch S...

Page 4: ...me isotropic The LCDdisplay liquidcontainsa powerful irritant Incase of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medica...

Page 5: ...se Keep the operatorpanel clean Emergency stopand othersafety functions may notbe controlled from the operator panel Do not use excessive force orsharpobjects when operatingthe touch screen 1 6 Servic...

Page 6: ...ouchscreen Do not use air guns water jets or steam to clean the surface of touchscreens as they may damage touchscreen functionality If condiments food or drinks are spilled on the surface of the touc...

Page 7: ...BL 12V SL RO CO web SoftControl SoftMotion High Brightness High performance Black 12 Volt Sealed Rugged Only Certification Only Examples X2 base 5 v2 X2 pro 7 X2 control 10 X2 marine 12 SC X2 marine 1...

Page 8: ...river Do the following 1 Unpackand check the delivery If damage isfound notify the supplier Note Place the operator panelon a stable surface duringinstallation Dropping the operator panel or letting i...

Page 9: ...nd polarity of the powersource is correct Separate high voltage cables from signal and supply cables Shielded communication cables are recommended 24V DC RS232 RS422 RS485 24V DC A D Controller Power...

Page 10: ...orfurtherdetailsor recommendations please refertothe supplier 3 2 3 Open Ports In the rmware there are some ports thatare openby default due to the operating system orthat the internal application req...

Page 11: ...erial Plastic Weight 0 56 kg CPU TI Sitara AM335x Single Core 600MHz TI AM3352BZCZ60 Serial port COM A Standard DSUB 9 pin female 1x RS232 RX TXwith RTS CTS 1x RS422 or 2x RS485 Serial port COM B N A...

Page 12: ...54 08 x 85 92 Pixel errors Class I ISO 9241 307 Backlight brightness 400 cd m2 Backlight lifetime 20000 hours Operating temperature 0 C 50 C Storage temperature 20 C 60 C Relative humidity in operatio...

Page 13: ...owderin solution 1 Gumption 1 SBP 60 95 1 Bleach 1 Hydrochloricacid 36 Sulfuricacid 10 Castoroil Linseed oil Tomato ketchup Causticsoda 40 1 Methanol Trichloroacetic acid 50 Cuttingoil Nitric acid 10...

Page 14: ...uene 5 hours The touch screen surface on the operatorpanel is made of polyester with a hard coattoresistscratchesandwithstand exposure to manysolvents without visible change 5 1 3 Touch Screen Protect...

Page 15: ...CLASS B Pin Signal Comment 1 Vin Main input supply voltage 2 Vin Power Ground 3 FG Frame Ground b COM A port connectorDSUB Short Name COM A De scrip tion DSUB 9 female right angle Refer ence Kycon K2...

Page 16: ...00 Mbit Ethernet RJ45 connector right angle tabup Refer ence CLASS C Pinoutaccording to Ethernet Standard for MDI Same as on PC Connector Shell housing is connected to Frame Ground d Primary USB Short...

Page 17: ...H350RR 03P CLASS C Pin Signal Comment 1 GND 2 RS485_ 3 RS485_ RS485 should use 5V signalinglevelon the bus side A Common mode filter is recommended for RS485 differentialpairs All signals should have...

Page 18: ...Operator PanelDrawings 6 2 X2base 7 v2Outline Note A Step CAD file is available on the web site www beijerelectronics com X2 base 7 v2 HP v2 HP X2 base 7 v2 Beijer Electronics MAEN329 18...

Page 19: ...Operator PanelDrawings Note Minimum thickness for the frontplate is 2 0 mm Beijer Electronics MAEN329 19...

Page 20: ...t terminalconnectoron the operatorpanel and the chassis of the panel see 2 in drawing above 2 Connect awire orgroundingbraid that is sized correctlyaccording to local electrical codes betweenthe chass...

Page 21: ...5 RJ45 RJ45 RJ45 Industrial Ethernet Operator panel Operator panel Operator panel Operator panel Shielded Short and unshielded 0 1 F 250 V 1 1 3 3 8 8 2 2 In some industrialunits forEthernet the RJ45...

Page 22: ...RS 232 communication Use twisted pairandshielded cabling forRS 422 and RS 485 Use the cablingintendedforthe bus type Ethernet Pro bus CC Link CAN Device Netetc Use the cablingintendedforthe bus type E...

Page 23: ...ablingmayremove minor disturbances Large ferrite piecesthat are snapped ontounshielded cablingand where the wires go2 4 times around the cores are approximately 5 25 times more ef cient 7 4 Ambient Te...

Page 24: ...thas aradiant heatvalue of 5 5 W m2 per degrees C Installinga fan inside the cabinetevens out the temperature while moving air providesconsiderably better coolingthan stillair Install the fan so that...

Page 25: ...tion against electric shock and UL 950 Note Here is an example that explains why a secure 24 V DC powersupply can be ruined by mixing 24 V relay contacts with 230 V AC relay contacts in a smaller cont...

Page 26: ...nst the 24 V DC powersupply butnogalvanic isolation between the communication ports forRS 232 RS 422 RS 485 and USB Only the Ethernet connectionhas galvanic isolation The operatorpanel has galvaniciso...

Page 27: ...ngpoints there is a substantial risk of problems Groundingcurrents go through communication cables the rearplate of the controller internally in the operatorpanel and can cause errors Use external uni...

Page 28: ...e shield mustbe grounded at one end The other end is usuallygrounded but with longerdistances or whenthere is adifference in the ground potential the shield should be connected tothe ground via 0 1 F...

Page 29: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...

Reviews: