background image

Foreword

Installation manual for iX Panel T4A

Foreword

All iX Panels are developed to satisfy the demands of human-machine
communication. Built-in functions such as displaying and controlling text,
dynamic indication, time channels, alarm and recipe handling are included.
The operator panel works primarily in an object-oriented way, making it easy to
understand and use. Configuration is carried out on a PC using the iX Developer
configuration tool. The project can then be transferred and stored in the operator
panel itself.
Various types of automation equipment such PLCs, servos or drives can be
connected to the iX Panels. In this manual, the term “the controller” refers to the
connected equipment.
This manual explains how to install the operator panel. Please refer to the iX
Developer reference manual for further information.

Order no: MAEN015A

Copyright © 2011-05 Beijer Electronics AB. All rights reserved.

The information in this document is subject to change without notice and is provided as available at the

time of printing. Beijer Electronics AB reserves the right to change any information without updating this

publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.

Read the entire installation manual prior to installing and using this equipment. Only qualified personnel

may install, operate or repair this equipment. Beijer Electronics AB is not responsible for modified, altered

or renovated equipment. Because the equipment has a wide range of applications, users must acquire the

appropriate knowledge to use the equipment properly in their specific applications. Persons responsible

for the application and the equipment must themselves ensure that each application is in compliance with

all relevant requirements, standards and legislation in respect to configuration and safety. Only parts and

accessories manufactured according to specifications set by Beijer Electronics AB may be used.

BEIJER ELECTRONICS AB SHALL NOT BE LIABLE TO ANYONE
FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM THE
INSTALLATION, USE OR REPAIR OF THIS EQUIPMENT, WHETHER
ARISING IN TORT, CONTRACT, OR OTHERWISE. BUYER'S SOLE
REMEDY SHALL BE THE REPAIR, REPLACEMENT, OR REFUND
OF PURCHASE PRICE, AND THE CHOICE OF THE APPLICABLE
REMEDY SHALL BE AT THE SOLE DISCRETION OF BEIJER
ELECTRONICS AB .

Beijer Electronics, MAEN015A

Summary of Contents for iX Panel T4A

Page 1: ...iX Panel T4A Installation Manual English MAEN015A 2011 05...

Page 2: ...updating this publication Beijer Electronics AB assumes no responsibility for any errors that may appear in this document Read theentireinstallation manual prior to installing and using this equipmen...

Page 3: ...a 10 4 ChemicalResistance 12 4 1 MetalCasing 12 4 2 Touch Screen and Overlay 13 4 2 1 Autotex F157 207 13 4 2 2 Touch Screen Surface 14 4 2 3 Auto ex EB 14 5 Operator Panel Drawings 15 5 1 Communicati...

Page 4: ...of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves an illustrative purpose Be...

Page 5: ...cleaningormaintenance operations disconnect the equipment from the electrical supply Clean the display and surroundingfront cover with asoft cloth and mild detergent Replacingthe battery incorrectly...

Page 6: ...installation plate thickness 11 mm Space requirements when installingthe operatorpanel 100 mm 100 mm 145 mm 104 mm 50 mm 50 mm 43 mm 100 mm Caution The openings on the enclosure are for airconvection...

Page 7: ...ing it or letting itfall may cause damage 2 Use the cut out dimensions thatare included on the outline drawingto cut acorrectopeningin the cabinet A separate cut out drawingisavailable for download fr...

Page 8: ...shielded communication cables Separate high voltage cables from signal and supply cables 24V DC RS232 RS422 RS485 24V DC A D Controller Power B Ethernet C Connect cable A Connect cable B usingan M5 sc...

Page 9: ...rator panelto the controller please refer to the help le for the driverin question 2 2 2 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe applicati...

Page 10: ...port for COM3 RS232 and COM4 RS422 RS485 9 pin D sub contact with RS422 RTS chassis mounted female with standard locking screws 4 40 UNC Ethernet 1 x 10 Base T 100 Base T shielded RJ 45 USB 1 x USB H...

Page 11: ...ature 20 to 85 C depending on display Relative humidity 95 non condensed Approvals and certifications Information is available on the web site www beijerelectronics com See section ChemicalResistance...

Page 12: ...llowing chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above c...

Page 13: ...acid 50 Gumption1 SBP 60 951 Ariel powderin solution1 Hydrochloric acid 36 Sulfuric acid 10 Bleach1 Linseed oil Tomato ketchup Castoroil Methanol Trichloroacetic acid 50 Causticsoda 40 1 Nitric acid...

Page 14: ...4 2 3 Autoflex EB It is recommended to use the Auto ex EB touch display protection lm thatcan be ordered from BeijerElectronics Solvent Resistance Auto ex EBwithstands exposure to the same chemicalsa...

Page 15: ...port 9 pin female Pin COM1 COM2 COM3 COM4 1 RS422 TX RS485 TX RX RS422 TX RS485 TX RX 2 RS232 RX RS232 RX 3 RS232 TX RS232 TX 4 RS422 RX RS422 RX 5 GND GND GND GND 6 RS422 TX RS485 TX RX RS422 TX RS4...

Page 16: ...iX PanelT4A Outline 7 max 11 mm material thickness 43 145 104 87 9 9 128 9 9 USB host SD memory card slot COM3 RS 232 COM4 RS422 RS485 COM1 RS232 COM2 RS422 RS485 Ethernet 24 V DC Expansion port Beij...

Page 17: ...assis and the closest groundingpoint on the door see 3 in drawingabove 3 Connect astrongbut shortgroundingbraid betweenthe doorand the device cabinet see 4 indrawingabove 4 Twist the cables onto the 2...

Page 18: ...nithas its shield directly grounded or groundedviaa capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate Hum or grounding loops canoccur U...

Page 19: ...s to connect the otherend of the shield to the ground via a 0 1 uF 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms...

Page 20: ...ted average temperature in the cabinet as wellas a large program for controllingthe temperature in the device cabinet An enamel coated steel cabinethasaradiant heatvalue of 5 5 W m2 and degrees C Inst...

Page 21: ...LV accordingtoEN 60950 protectionagainst electric shock and UL 950 Example Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay co...

Page 22: ...SB memory stick keyboard or similardevice is plugged in If anumberofunitsare connectedthat have a0 Vand a groundconnection and these are connected to various groundingpoints there is a substantial ris...

Page 23: ...ires may be onthe same levelor require pull up orpull downtoensure that no faultysignals are detected when the busisin restingmode all transmittersare disconnected 1 2 3 4 5 V 0 V 1 K 1 K 120 ohm 120...

Page 24: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...