Image and CODESYS update
Note:
Image loader for iX TxA and X2 base only supports updating panel image using ethernet.
5.1.2
Image + new iX Developer project
It is possible to upgrade both the panel image and the iX Developer project on an
operator panel. This is done in two steps:
1. Create a panel image USB flash drive or SD card using the Image Loader
utility.
2. Export the iX Developer project from within iX Developer, to that same USB
flash drive or SD card.
5.2 Updating the panel image over
ethernet
The Image Loader utility can be used to upgrade the panel image over ethernet.
Note:
Before trying to update the panel over ethernet, make sure that your PC is on the same
IP-subnet as the operator panel. If your panel has an IP address of 192.168.1.1, and
a netmask of 255.255.255.0 , then your PC has to have an IP address in the range of
192.168.1.2 – 192.168.1.254 and a netmask of 255.255.255.0, in order to be able to
communicate with the panel.
To enter the update mode on a iX TxA or X2 base, press a finger on the screen and apply
power to the panel.
1. Enter the panel target IP address in the dialog and click on
Update
to start the
update.