Function and area of use 

This document explains how to set up a QnUDE to communicate with X2/BoX2 over Ethernet.  
 

2

 

About this Startup document 

This Startup document should not be considered as a complete manual. It is an aid to be able to 

Startup a normal application quickly and easily. 

 
Use the following hardware, software, drivers and utilities in order to obtain a stable application: 

 

In this document we have used following software and hardware 

 

iX Developer 2.40 SP4 or later 

 

X2/BoX2 series 

 

GX Works 3 

 

QnUDE CPU with built in Ethernet 

 

 

For further information refer to 

 

Beijer Electronics knowledge database, HelpOnline

 

 
This document and other Startup documents can be obtained from our homepage. 

Please use the address 

[email protected]

 for feedback about our Quick Start 

documents. 

 

 

Copyright © Beijer Electronics, 2020 

 

This documentation (below referred to as ‘the material’) is the property of Beijer Electronics. The holder or user has a non-

exclusive right to use the material.  
The holder is not allowed to distribute the material to anyone outside his/her organization except in cases where the material is 
part of a system that is supplied by the holder to his/her customer.  
The material may only be used with products or software supplied by Beijer Electronics.  

Beijer Electronics assumes no responsibility for any defects in the material, or for any consequences that might arise from the use of 
the material. 
It is the responsibility of the holder to ensure that any systems, for whatever applications, which is based on or includes the 
material (whether in its entirety or in parts), meets the expected properties or functional requirements. 
Beijer Electronics has no obligation to supply the holder with updated versions.

 

Summary of Contents for SUEN00403

Page 1: ...Quick Start Guide MELSEC QnUDE Ethernet to X2 series SUEN00403 Quick start Ethernet communication...

Page 2: ...urope beijerelectronics com for feedback about our Quick Start documents Copyright Beijer Electronics 2020 This documentation below referred to as the material is the property of Beijer Electronics Th...

Page 3: ...tents 1 Function and area of use 2 2 About this Startup document 2 3 Table of Contents 3 4 Setting in QnUDE Ethernet communication 4 5 Setting in X2 BoX2 Ethernet communication 5 Create a new project...

Page 4: ...uilt in Ethernet port open settings located in PLC Parameter Enter IP address Subnet Mask and if used Default Gateway Port no in decimal Select protocol UDP and set station port number setting range 1...

Page 5: ...5 Setting in X2 BoX2 Ethernet communication The following chapter describes how to setup the Ethernet communication in iX Devloper using the MC Protocol driver connecting to QnUDE Create a new project...

Page 6: ...QnUDE Ethernet X2 BoX2 series SUEN00403 2020 10 6 8 Normal dotm 2020 09 09 When creating a new project or adding changing controller Select MC Protocol Type path and project name...

Page 7: ...03 2020 10 7 8 Normal dotm 2020 09 09 Driver setting MC Protocol Double click on Tags Select Controllers Settings Select UDP and Hexadecimal Type IP address and port number stated in GX Works3 Tip Hel...

Page 8: ...ns digitalization display solutions and support As experts in user friendly software hardware and services for the Industrial Internet of Things we empower you to meet your challenges through leading...

Reviews: