Safety Precautions

1

Safety Precautions

Both the installer and the owner and/or operator of the operator panel must read
and understand this installation manual.

1.1 General

Read the safety precautions carefully.

Check the delivery for transportation damage. If damage is found, notify the
supplier as soon as possible.

The supplier is not responsible for modified, altered or reconstructed

equipment.

Use only parts and accessories manufactured according to specifications of
the supplier.

Read the installation and operating instructions carefully before installing,
using or repairing the operator panel.

Never allow fluids, metal filings or wiring debris to enter any openings in the
operator panel. This may cause fire or electrical shock.

Only qualified personnel may operate the operator panel.

Storing the operator panel where the temperature is lower/higher than
recommended in this manual can cause the LCD display liquid to
congeal/become isotopic.

The LCD display liquid contains a powerful irritant. In case of skin contact,
wash immediately with plenty of water. In case of eye contact, hold the eye
open, flush with plenty of water and get medical attention.

The figures in this manual serves an illustrative purpose. Because of the many
variables associated with any particular installation, the supplier cannot
assume responsibility for actual use based on the figures.

The supplier neither guarantees that the operator panel is suitable for your
particular application, nor assumes responsibility for your product design,
installation or operation.

It is recommended to turn on and shut down the operator panel at least once
before installing any components/cards or before connecting the operator
panel to external devices, like for example serial devices.

1.2 UL and cUL Installation

Caution:

This section is only valid for UL labeled EXTER T60/T60m panels.

This equipment is suitable for use in non-hazardous locations only.
[Combinations of equipment in your system are subject to investigation by
the local authority having jurisdiction at the time of installation].

All devices have to be supplied by a Class 2 power supply.

Beijer Electronics, MAEN809F

4

Summary of Contents for EXTER T60

Page 1: ...EXTER T60 T60m Installation Manual English MAEN809F 2014 11...

Page 2: ...t updating this publication Beijer Electronics AB assumes no responsibility for any errors that may appear in this document Read theentireinstallation manual prior to installing and using this equipme...

Page 3: ...0 3 TechnicalData 11 4 ChemicalResistance 13 4 1 MetalCasing 13 4 2 Touch Screen and Overlay Material 13 4 2 1 Autotex F157 207 13 4 2 2 Touch Screen Surface 14 4 2 3 Touch Screen Protector 15 5 Opera...

Page 4: ...powerful irritant Incase of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves...

Page 5: ...This product contains a battery this must onlybe changedin an areaknown tobe non hazardous Replace the battery with aCR2450 battery Use of anothertype ofbattery maypresent a risk of re orexplosion Wa...

Page 6: ...oweroutlet Peripheral equipment must be appropriate forthe application and location 1 4 During Use Keep the operatorpanel clean Emergency stopand othersafety functions may notbe controlled from the op...

Page 7: ...ch 100 mm 4 0 inch 57 mm 2 24 inch 7 95 inch 5 98 inch Caution The openings on the enclosure are for airconvection Do not cover these openings 2 2 Installation Process 1 Unpackand check the delivery I...

Page 8: ...operator panelistobe situated draw along the outer sides ofthe holesandcutaccording to the markings 3 Secure the operator panel in position usingallthe fasteningholesand the provided brackets and scre...

Page 9: ...ise errors in communication may occur Ensure that the voltage and polarity of the powersource is correct Separate high voltage cables from signal and supply cables Shielded communication cables are re...

Page 10: ...ections to the Controller For information aboutthe cables to be used when connecting the operator panelto the controller please refer to the help le for the driverin question 2 2 3 Other Connections a...

Page 11: ...06 ppm C2 Real time clock battery CR2450 UL and cUL Sanyo or Panasonic Minimum lifetime 3 years Power consumption at rated voltage Normal 0 2 A Maximum 0 4 A For T60c and for T60m with hardware versio...

Page 12: ...50 C Horizontal installation 0 to 40 C Storage temperature 20 to 70 C Relative humidity 5 85 non condensed Approvals and certifications Information is available on the web site www beijerelectronics c...

Page 13: ...Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above chemicals is demanded itis recommended to first test the chem...

Page 14: ...l Windex1 Cyclohexanol Persil powderin solution1 Wisk Diacetone alcohol Petroleum spirit1 1 Extremely faintglossingof the texture was noted Autotex withstands DIN 42 115 Part2 exposure of up to 1 hour...

Page 15: ...een Protector For harsh environments and exposure tooutdoorconditions it isrecommended to use a protective lm toguardthe touch screenfromdamage These optional parts can be ordered from Beijer Electron...

Page 16: ...Operator PanelDrawings 5 Operator Panel Drawings 5 1 Communication Ports RS 232 RS 422 RS 422 485 RS 485 Ethernet USB Beijer Electronics MAEN809F 16...

Page 17: ...Operator PanelDrawings 5 2 EXTER T60 T60m Outline Beijer Electronics MAEN809F 17...

Page 18: ...aid between the panel s chassis and the closest groundingpoint on the door see 3 in drawingabove 3 Connect astrongbut shortgroundingbraid betweenthe doorand the device cabinet see 4 indrawingabove 4 T...

Page 19: ...nithas its shield directly grounded or groundedviaa capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate Hum or grounding loops canoccur U...

Page 20: ...e shield to the ground via a 0 1 F 250 Vplastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 Hz groun...

Page 21: ...a large program for controllingthe temperature in the device cabinet An enamel coated steel cabinethasaradiant heatvalue of 5 5 W m2 and degrees C Installinga fan inside the cabinetwill even out the...

Page 22: ...LVaccording to EN 60950 protection against electric shock andUL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay cont...

Page 23: ...SB memory stick keyboard or similardevice is plugged in If anumberofunitsare connectedthat have a0 Vand a groundconnection and these are connected to various groundingpoints there is a substantial ris...

Page 24: ...ires may be onthe same levelor require pull up orpull downtoensure that no faultysignals are detected when the busisin restingmode all transmittersare disconnected 1 2 3 4 5 V 0 V 1 K 1 K 120 ohm 120...

Page 25: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...

Reviews: