The available outputs devices are: 
 

Subject1-headphones. (stereo) 

 

PC input audio Line-in. (stereo) 

 

Subject2-headphones. (stereo) 

 

Speakers. (stereo) 

 

Monitor-headphones. (stereo) 

Make sure that the needed devices are connected and switched on. By default the Behringer and the 
Speakers are activated already or they are activated when the lab-computer is turned on. Some 
microphones should be turned on separately. 

 

Start the program. 

 

 

First the ‘Beer’ program automatically looks for the Behringer mixer to make a connection (see.get ip: 
192.168.1.1). After the connection has been set up the program initializes (resets!) the Behringer 
(see.use:192.168.1.1) automatically. 
By default all input and output volumes are set at their lowest levels and no selections from input to 
output are made. (everything is ‘off’) 
 

Create the settings for your experiment: 

At the bottom left you see the available inputs with their corresponding volume setting above this.  
The input options are: 
 

-‘mic1’, Subject1-microphone. (mono) 

To detect and record speech responses. VU-meter shown.

 

 

-‘mic2’, Subject2-microphone. (mono) 

To detect and record speech responses. VU-meter shown.

 

 

-‘PC out’, PC output audio line-out. (stereo) 

To present stimuli or feedback audio. VU-meter shown.

 

The left top has selectable squares to connect the input below to a specific output on the right. 
The destinations here are connected to the noted devices with their individual volume control. 
 

 

Summary of Contents for Xair18

Page 1: ...hroughout all experiment sessions PC Line OUT R PC Line OUT L PC Line IN R PC Line IN L Phones Exp R Phones Exp L Behringer Input 3 Behringer Input 4 MIC IN Subject 1 MIC IN Subject 2 Behringer AUX 1 Behringer AUX 2 Behringer Control L Behringer Control R Phones Sub 1 L Phones Sub 1 R Behringer AUX 5 Behringer AUX 6 Behringer Input 1 Behringer Input 2 Phones Sub 2 L Phones Sub 2 R Behringer Main L...

Page 2: ...the Behringer see use 192 168 1 1 automatically By default all input and output volumes are set at their lowest levels and no selections from input to output are made everything is off Create the settings for your experiment At the bottom left you see the available inputs with their corresponding volume setting above this The input options are mic1 Subject1 microphone mono To detect and record spe...

Page 3: ...device front of the device at the right bottom with a 6 35mm stereo Jack connector Next to the Jack socket there is a volume control that controls the volume of this output directly this does not influence your other volumes and settings In the application you can determine which output you want to monitor from the pull down menu The monitor options are phones 1 PC in phones 2 speakers Make your c...

Page 4: ...y pressing in the top menu the option File Then select save file and select the location within your experiment folder in E data userfiles yourfolder Additionally make a backup of this file on a drive that is backed up automatically DRDR workgroup files The default extension for these files is scn At the start of each measurement session load your own settings file by selecting open file in the me...

Page 5: ...Cabin R PC Behringer Behringer 1 setup TSG Extra UTP Card in PC connection IP 192 168 1 101 Behringer set as DHCP server IP 192 168 1 1 Radboud University Nijmegen FSW TSG june 2017 USB 2 0 to USB PC connection You can see that some of the mono inputs and outputs are combined into stereo inputs and outputs The initial setup in the research labs will make use of the audio connections of the lab com...

Page 6: ...6 With kind regards TSG ...