Behringer ULTRAMIZER PRO DSP1424P User Manual Download Page 2

2

ULTRAMIZER PRO DSP1424P

     

This symbol, wherever it appears, alerts

you to important operating and mainte-

nance instructions in the accompanying

literature. Read the manual.

SAFETY  INSTRUCTIONS

CAUTION: To reduce the risk of electric shock, do not remove the

cover (or back). No user serviceable parts inside; refer

servicing to qualified personnel.

WARNING: To reduce the risk of fire or electric shock, do not expose

this device to rain or moisture.

DETAILED SAFETY INSTRUCTIONS:

All the safety and operation instructions should be read before the device is operated.

Retain Instructions:

The safety and operating instructions should be retained for future reference.

Heed Warnings:

All warnings on the device and in the operating instructions should be adhered to.

Follow instructions:

All operation and user instructions should be followed.

Water and Moisture:

The device should not be used near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet

basement, or near a swimming pool etc.).

Ventilation:

The device should be situated so that its location or position does not interfere with its proper ventilation. For

example, the device should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation

openings, or placed in a built-in installation, such as a bookcase or cabinet that may impede the flow of air

through the ventilation openings.

Heat:

The device should be situated away from heat sources such as radiators, heat registers, stoves, or other

devices (including amplifiers) that produce heat.

Power Source:

The device should be connected to a power supply only of the type described in the operating instructions or as

marked on the device.

Grounding or Polarization:

Precautions should be taken so that the grounding or polarization means of an device is not defeated.

Power-Cord Protection:

Power cords should be routed so that they are not likely to be walked on or pinched by items placed upon or

against them, paying particular attention to cords and plugs, sockets, outlets and the point where they exit

from the device.

Cleaning:

The device should be cleaned only as recommended by the manufacturer.

Non-use Periods:

The power cord of the device should be unplugged from the outlet when left unused for a long period of time.

Debris and Liquid Entry:

Debris and/or liquids should not be allowed to enter the enclosure through openings.

Damage Requiring Service:

The device should be serviced by qualified service personnel when:

- The power supply cord or the plug has been damaged; or

- Debris or liquid has entered the device; or

- The device has been exposed to rain; or

- The device does not appear to operate normally or exhibits a marked change in performance; or

- The device has been dropped, or the enclosure damaged.

Servicing:

The user should not attempt to service the device beyond that which is described in the operating instructions.

All other servicing should be referred to qualified service personnel.

This  symbol,  wherever  it  appears,

alerts  you  to  the  presence  of

uninsulated dangerous voltage inside

the enclosure—voltage that may be

sufficient to constitute a risk of shock.

All manuals and user guides at all-guides.com

Summary of Contents for ULTRAMIZER PRO DSP1424P

Page 1: ...Version 1 0 September 2002 User s Manual ENGLISH ULTRAMIZER PRO DSP1424P www behringer com All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...evices including amplifiers that produce heat Power Source The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device Groundin...

Page 3: ...INGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality manufa...

Page 4: ...reates an incredible bass sound below your loudspeaker s frequency range s Incorporated leveler for constant average output level while retaining the instantaneous dynamics s Free ULTRAMIZER software...

Page 5: ...ULTRAMIZER PRO in analog recording 16 3 2 2 The ULTRAMIZER PRO in digital recording and sampling 16 3 2 3 The ULTRAMIZER PRO in mastering 16 3 3 The ULTRAMIZER PRO as a protective device 17 3 3 1 Prot...

Page 6: ...spectrum into two bands prior to performing the dynamic functions This enables a very musical and effective compression of the program material signal On top of that the ULTRAMIZER PRO also features a...

Page 7: ...RO is equipped with ten illuminated parameter keys one jog wheel rotary control a numeric display 8 LED indicators and a power switch Each of the two fully independent channels can be monitored with f...

Page 8: ...ight up in the display can be adjusted The subjec tively felt density of the program material is the result of the amount of compression that is applied The DENSITY can be adjusted from 0 no compressi...

Page 9: ...can be adjusted ranging from 0 to 100 PROC will light up b Pressed a second time the TUNE parameter can be set Hz will light up Here the TUNE control sets the upper cut off frequency of the super bass...

Page 10: ...selected voltage Please note that depending on the mains voltage supplied to the unit the correct fuse type and rate must be installed see chapter 6 SPECIFICATIONS Please use the enclosed mains cable...

Page 11: ...ill perform as a brick wall limiter which will affect transients ULTRAMIZERRANGE The parameter RANGE which you access after pressing the ULTRAMIZER key three times determines the maximal gain the Ultr...

Page 12: ...parameter 2 1 5 The 3D Surround function With the the 3D surround function the ULTRAMIZER PRO can be used as a 3D stereo surround processor increasing the stereo width of the program material Whether...

Page 13: ...wer right corner of the display After loading the data the ULTRAMIZER PRO enables the preset and the dot disappears This brief interruption avoids the direct activation of every preset as you scroll t...

Page 14: ...nge setup The display reads a capital P program Here too four modes can be selected with the jog wheel as follows LVSOD 0RGH 0 No program change data are transmitted 1 Program change data are received...

Page 15: ...MIZER PRO We are currently developing a software editor which will allow for storing single items of the unit s internal data on an external medium Thus it will be possible to archive ULTRAMIZER PRO s...

Page 16: ...d In extreme cases it will cause distortion due to tape saturation In contrast to analog side effects in the digital field always become extremely audible with decreasing level a tape previously recor...

Page 17: ...e damaged by an occasional high level overload e g the sound of a microphone falling onto a hard floor In order to protect a system or the loudspeak ers the application of the BEHRINGER ULTRAMIZER PRO...

Page 18: ...he dynamic functions of the crossover 3 4 The ULTRAMIZER PRO in combination with a multitrack In connection with multi track machines the BEHRINGER ULTRAMIZER PRO can be used to prevent distor tion ca...

Page 19: ...mit with the highest obtainable average level and use a multiplicity of signal processors to achieve this despite the effects on the quality of the program material If a limiter with active pre emphas...

Page 20: ...ish to save When the preset is activated its parameters are transmitted as controller data and can be recorded on a sequencer or similar device Repeat this routine until all presets of your choice hav...

Page 21: ...IMPORTANT This does not apply for general export models which are built for one operating voltage only The AC voltage selection is defined by the position of the fuse holder If you intend to change th...

Page 22: ...22 ULTRAMIZER PRO DSP1424P Fig 4 1 Different plug types 4 INSTALLATION All manuals and user guides at all guides com...

Page 23: ...X X Notes O YES X NO Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO Tab 5 1 MIDI implementation chart Parameter Name Display Range Midi Controller Number Controller...

Page 24: ...socket IN OUT THRU Digital processing Converters 24 bit Sigma Delta 64 128 times oversampling Sampling rate 46 875 kHz Display Type 2 digit numeric LED display Power supply Mains Voltages USA Canada...

Page 25: ...placed within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local le...

Reviews: