Behringer ULTRAMIZER PRO DSP1424P User Manual Download Page 15

15

                                           ULTRAMIZER PRO DSP1424P

The MIDI button LED flashes signaling that SYSEX data is being received. “d2” will enable the ULTRAMIZER PRO

to send a “bulk dump”. Start your sequencer and press PRESET on the unit to start the transmission.
If you press the IN/OUT key again on the sixth page, the ULTRAMIZER PRO quits MIDI setup mode.
To load these settings again, select “d1”, press PRESET and start your sequencer. If you press IN/OUT again,

you will leave the MIDI setup. You can at all times press any other key to leave the MIDI setup directly.

+

During a bulk dump all audio functions of the ULTRAMIZER PRO will be deactivated.

The  full-featured  MIDI  implementation  of  the  ULTRAMIZER PRO  allows  for  easily  integrating  the

ULTRAMIZER PRO  into  any  MIDI  system.  For  detailed  information  on  controller  tabs  please  refer  to

section 5 “APPENDIX”.

s

MIDI IN

Any MIDI data sent to the ULTRAMIZER PRO (sequencer, MIDI footswitch, etc.) are received via the MIDI IN

jack. For example, if you wish to use the ULTRAMIZER PRO as an effects device for your guitar rack, you can

connect the MIDI IN jack to a MIDI footswitch (our BEHRINGER MIDI FOOT CONTROLLER FCB1010) that

allows for selecting program presets. If your rack includes another MIDI effects device (e.g. a multi-effects

processor), the data sent from the MIDI footswitch can be routed via the ULTRAMIZER PROs MIDI THRU jack

to your multi-effects processor.

s

MIDI THRU

The MIDI THRU jack is used to loop through incoming MIDI data, i.e. any control data received at the MIDI IN

of the ULTRAMIZER PRO will be transmitted via the MIDI THRU jack to other MIDI devices/instruments.

s

MIDI OUT

The MIDI OUT jack allows for transmitting MIDI data that originate from the ULTRAMIZER PRO. We are

currently developing a software editor which will allow for storing single items of the unit’s internal data on an

external medium. Thus, it will be possible to archive ULTRAMIZER PRO settings and presets on a computer,

sequencer or MIDI data recorder. Both MIDI control change and MIDI program change commands will be

transmitted when you edit or recall filter settings. Detailed information on this future software editor are available

from our BEHRINGER hotline (phone: +49 (0) 2154-920666) and/or our internet homepage (www.behringer.com).

3. APPLICATIONS

The BEHRINGER ULTRAMIZER PRO features a high level of flexibility. The following chapter describes some

standard applications of your ULTRAMIZER PRO.

3.1 Level setting

Take care to set levels properly on the ULTRAMIZER PRO! Low levels deteriorate the dynamics of the music

signal, which results in a poor, weak and noisy sound. On the other hand, very high levels overdriving the

converters in the ULTRAMIZER PRO should also be avoided. Digital distortion is (unlike its analog counterpart)

very unpleasant as it does not occur gradually but abruptly.
Use the input level meter of the ULTRAMIZER PRO to adjust the input signal to about -10 dB. Make sure that

the CLIP LED never lights up!

3.2 Using the ULTRAMIZER PRO in a studio environment

With its highly flexible configuration the ULTRAMIZER PRO also delivers good results in a professional studio

or  home  recording  environment.  When  used  as  a  mastering  device  while  recording  or  copying,  the

ULTRAMIZER PRO should be placed between source and recorder as shown in fig 3.1. You can realize any

application ranging from slight processing to the total manipulation of music signals. For example, you can use

the ULTRAMIZER PRO as a loudness maximizer, limiter and the denoiser system at the same time when

copying analog tapes.

3. APPLICATIONS

All manuals and user guides at all-guides.com

Summary of Contents for ULTRAMIZER PRO DSP1424P

Page 1: ...Version 1 0 September 2002 User s Manual ENGLISH ULTRAMIZER PRO DSP1424P www behringer com All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...evices including amplifiers that produce heat Power Source The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device Groundin...

Page 3: ...INGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality manufa...

Page 4: ...reates an incredible bass sound below your loudspeaker s frequency range s Incorporated leveler for constant average output level while retaining the instantaneous dynamics s Free ULTRAMIZER software...

Page 5: ...ULTRAMIZER PRO in analog recording 16 3 2 2 The ULTRAMIZER PRO in digital recording and sampling 16 3 2 3 The ULTRAMIZER PRO in mastering 16 3 3 The ULTRAMIZER PRO as a protective device 17 3 3 1 Prot...

Page 6: ...spectrum into two bands prior to performing the dynamic functions This enables a very musical and effective compression of the program material signal On top of that the ULTRAMIZER PRO also features a...

Page 7: ...RO is equipped with ten illuminated parameter keys one jog wheel rotary control a numeric display 8 LED indicators and a power switch Each of the two fully independent channels can be monitored with f...

Page 8: ...ight up in the display can be adjusted The subjec tively felt density of the program material is the result of the amount of compression that is applied The DENSITY can be adjusted from 0 no compressi...

Page 9: ...can be adjusted ranging from 0 to 100 PROC will light up b Pressed a second time the TUNE parameter can be set Hz will light up Here the TUNE control sets the upper cut off frequency of the super bass...

Page 10: ...selected voltage Please note that depending on the mains voltage supplied to the unit the correct fuse type and rate must be installed see chapter 6 SPECIFICATIONS Please use the enclosed mains cable...

Page 11: ...ill perform as a brick wall limiter which will affect transients ULTRAMIZERRANGE The parameter RANGE which you access after pressing the ULTRAMIZER key three times determines the maximal gain the Ultr...

Page 12: ...parameter 2 1 5 The 3D Surround function With the the 3D surround function the ULTRAMIZER PRO can be used as a 3D stereo surround processor increasing the stereo width of the program material Whether...

Page 13: ...wer right corner of the display After loading the data the ULTRAMIZER PRO enables the preset and the dot disappears This brief interruption avoids the direct activation of every preset as you scroll t...

Page 14: ...nge setup The display reads a capital P program Here too four modes can be selected with the jog wheel as follows LVSOD 0RGH 0 No program change data are transmitted 1 Program change data are received...

Page 15: ...MIZER PRO We are currently developing a software editor which will allow for storing single items of the unit s internal data on an external medium Thus it will be possible to archive ULTRAMIZER PRO s...

Page 16: ...d In extreme cases it will cause distortion due to tape saturation In contrast to analog side effects in the digital field always become extremely audible with decreasing level a tape previously recor...

Page 17: ...e damaged by an occasional high level overload e g the sound of a microphone falling onto a hard floor In order to protect a system or the loudspeak ers the application of the BEHRINGER ULTRAMIZER PRO...

Page 18: ...he dynamic functions of the crossover 3 4 The ULTRAMIZER PRO in combination with a multitrack In connection with multi track machines the BEHRINGER ULTRAMIZER PRO can be used to prevent distor tion ca...

Page 19: ...mit with the highest obtainable average level and use a multiplicity of signal processors to achieve this despite the effects on the quality of the program material If a limiter with active pre emphas...

Page 20: ...ish to save When the preset is activated its parameters are transmitted as controller data and can be recorded on a sequencer or similar device Repeat this routine until all presets of your choice hav...

Page 21: ...IMPORTANT This does not apply for general export models which are built for one operating voltage only The AC voltage selection is defined by the position of the fuse holder If you intend to change th...

Page 22: ...22 ULTRAMIZER PRO DSP1424P Fig 4 1 Different plug types 4 INSTALLATION All manuals and user guides at all guides com...

Page 23: ...X X Notes O YES X NO Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO Tab 5 1 MIDI implementation chart Parameter Name Display Range Midi Controller Number Controller...

Page 24: ...socket IN OUT THRU Digital processing Converters 24 bit Sigma Delta 64 128 times oversampling Sampling rate 46 875 kHz Display Type 2 digit numeric LED display Power supply Mains Voltages USA Canada...

Page 25: ...placed within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local le...

Reviews: