background image

2

ULTRA-GRAPH PRO GEQ3102

This symbol, wherever it appears, alerts

you  to  the  presence  of  uninsulated

dangerous voltage inside the enclosure

-  voltage  that  may  be  sufficient  to

constitute a risk of shock.

This symbol, wherever it appears, alerts

you  to  important  operating  and

maintenance  instructions  in  the

accompanying  literature.  Read  the

manual.

SAFETY  INSTRUCTIONS

CAUTION: To reduce the risk of electric shock, do not remove

the cover (or back). No user serviceable parts inside;

refer servicing to qualified personnel.

WARNING: To reduce the risk of fire or electric shock, do not

expose this appliance to rain or moisture.

DETAILED SAFETY INSTRUCTIONS:

All the safety and operation instructions should be read before the appliance is operated.

Retain Instructions:

The safety and operating instructions should be retained for future reference.

Heed Warnings:

All warnings on the appliance and in the operating instructions should be adhered to.

Follow instructions:

All operation and user instructions should be followed.

Water and Moisture:

The appliance should not be used near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a

wet basement, or near a swimming pool etc.).

Ventilation:

The appliance should be situated so that its location or position does not interfere with its proper ventilaton.

For example, the appliance should not be situated on a bed, sofa rug, or similar surface that may block the

ventilation openings: or placed in a built-in installation, such as a bookcase or cabinet that may impede the

flow of air through the ventilation openings.

Heat:

The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other

appliances (including amplifiers) that produce heat.

Power Source:

The appliance should be connected to a power supply only of the type described in the operating instructions

or as marked on the appliance.

Grounding or Polarization:

Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.

Power-Cord Protection:

Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed

upon or against them, paying particular attention to cords and plugs, convenience receptacles and the point

where they exit from the appliance.

Cleaning:

The appliance should be cleaned only as recommended by the manufacturer.

Non-use Periods:

The power cord of the appliance should be unplugged from the outlet when left unused for a long period of

time.

Object and Liquid Entry:

Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.

Damage Requiring Service:

The appliance should be serviced by qualified service personnel when:

- The power supply cord or the plug has been damaged; or

- Objects have fallen, or liquid has been spilled into the appliance; or

- The appliance has been exposed to rain; or

- The appliance does not appear to operate normally or exhibits a marked change in performance; or

- The appliance has been dropped, or the enclosure damaged.

Servicing:

The user should not attempt to service the appliance beyond that which is described in the Operating Instructions.

All other servicing should be referred to qualified service personnel.

Summary of Contents for ULTRA-GRAPH PRO GEQ3102

Page 1: ...www behringer com Version 1 1 July 2000 User s Manual ULTRA GRAPH PRO GEQ3102 ENGLISH...

Page 2: ...ow of air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce he...

Page 3: ...t member of the BEHRINGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncomprom...

Page 4: ...igh and Low Cut filters remove unwanted frequencies e g floor rumble and tape hiss etc s Servo balanced inputs and outputs on gold plated XLR and 1 4 jack connectors s Relay controlled hard bypass wit...

Page 5: ...equalizer in sound reinforcement systems 9 2 2 Equalizer in the monitor path 10 2 2 1 Tuning in of a monitor system 10 2 3 Using the ULTRA GRAPH PRO in the studio 11 3 THE SOUND TOOL 11 3 1 Effects o...

Page 6: ...relays are also active at power on to isolate the unit from potentially damaging power on thump 1 2 Before you begin Your BEHRINGER ULTRA GRAPH PRO was carefully packed in the factory and the packagi...

Page 7: ...itch is released or the unit is switched off Use the AUDIO IN OUT switch to make A B comparisons between direct and processed signals 3 The LEVEL METER monitors the signal level to warn you of distort...

Page 8: ...5 V operation outside Europe you need to use a fuse of a higher rating see chapter 4 INSTALLATION 11 Use the enclosed power cord to connect the unit to the mains 12 SERIAL NUMBER Please take the time...

Page 9: ...ow band resonance should be eliminated with the ULTRA GRAPH PRO before you start doing a sound check Once this basic setting has been made you can continue to fine tune the system by hand Please remem...

Page 10: ...thod will give you valuable headroom Extremely low frequencies are usually faded out completely to avoid a stage sound that lacks transparency due to low frequency feedback Apply the low cut filter un...

Page 11: ...how to process typical frequency ranges of voices and instruments 3 THE SOUND TOOL In recording studios as well as stage or radio plays the ULTRA GRAPH PRO will be your valuable sound tool to modify...

Page 12: ...Hz can produce listening fatigue 5k to 8k Accentuation of percussion cymbals and snare drum Reduction at 5 kHz makes overall sound more distant and transparent Reduction of tape hiss and system noise...

Page 13: ...round connection For your own safety never remove or disable the ground conductor of the unit or of the AC power cable 4 3 Audio connections As standard the BEHRINGER ULTRA GRAPH PRO is installed with...

Page 14: ...Signal Tip hot ve Sleeve Ground Shield Sleeve Ground Shield Tip Tip Sleeve Sleeve Strain relief clamp Strain relief clamp Ring cold ve For connection of balanced and unbalanced plugs ring and sleeve h...

Page 15: ...ands ISO frequencies Bandwidth 1 3 octave Control range 6 dB or 12 dB switchable FUNCTION SWITCHES Audio in out switch to bypass the equalizer functions I O meter in out switches the meter display fro...

Page 16: ...n 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level in any c...