Behringer SU9920 User Manual Download Page 6

6

SONIC ULTRAMIZER SU9920

2. CONTROL ELEMENTS AND CONNECTIONS

CLIP:

 This LED is constantly lit when the input level is too

high. If it lights up for a short period of time it is warning
you of an impending overdrive. There is a safety headroom
of 3dBu before the signal becomes distorted. The LED
should not light up.

LEDs:

 The four LEDs display the output level in 10dBu

steps. Regular illumination of the 0dBu LED indicates an
optimal output level.

PROCESS:

 With this control the portion of high-frequency

signals to be processed by the SU9920 is specified. The
MAX setting corresponds to a level boost of +12dbU at
5kHz.

LOW CONTOUR:

 This control adjusts the portion of low-

frequency signals to be processed by the SU9920. The
MAX setting corresponds to a level boost of +12dbU at
50kHz.

IN/OUT:

 With this switch signal processing is activated

and deactivated. The LED lights up in the active operating
mode.

POWER:

 Use the POWER switch to put the unit into

operation. The POWER switch should be in the "Off"
position when you connect the unit to the power feed
(mains).

To disconnect the unit from the mains, pull out the power plug.
When switching on the unit ensure that the power plug is easily
accessible. To mount the unit in a rack ensure that the unit can
easily be disconnected from the mains by means of a plug or an
all-pole mains switch on the back side.

Please note: Switching the POWER switch off does
not disconnect the unit completely from the mains. For
this reason you should unplug the power cord if the
unit is not going to be used for prolonged periods of
time.

2. CONTROL ELEMENTS AND CONNECTIONS

2.1 Front panel

The control elements for CHANNEL 1 and CHANNEL 2 are identical. In the following paragraphs the functions are described using
CHANNEL 1 as an example.

Figure 2.1: Control elements on the front panel

2.2 Rear panel

Figure 2.2: Control elements on the rear panel

FUSE HOLDER / IEC POWER SOCKET:

 The mains

connection is made via an IEC male socket. It complies
with relevant safety regulations. A suitable power cord is
included. Replace the fuse with a fuse of the same type.

OUTPUTS 1:

 Balanced XLR sockets and ¼" jacks - these

are used to connect amplifiers as well as further signal
processors and recording devices. The jacks and XLR
sockets can be used in parallel when two outputs are
required.

INPUTS 1:

 Balanced XLR sockets and ¼" jacks - these

are used to connect line-level signal sources (e.g. a mixing
console). To avoid interference only the jacks or the XLR
sockets should be used.

SERIAL NUMBER:

 The serial number can be found on

the back right side of the unit. It is needed for online
registration.

01_DATA-MANFULL_SU9920_487_EN_Rev_A.pmd

19.04.2007, 14:43

6

Summary of Contents for SU9920

Page 1: ...SONIC ULTRAMIZER SU9920 User Manual Version 1 0 April 2007 01_DATA MANFULL_SU9920_487_EN_Rev_A pmd 19 04 2007 14 43 1...

Page 2: ...presence of uninsulated dangerous voltage inside the enclosure voltage that may be sufficient to constitute a risk of shock This symbol wherever it appears alerts you to important operating and maint...

Page 3: ...lly increases voice intelligibility and your music gains presence Guitar bass and keyboard rack improves articulation and restores cutting power often lost in miking and amplification Broadcasting and...

Page 4: ...as excellent technical and audio properties at an extremely reasonable price All of this will enable you to give free rein to your creativity without being hampered by budget constraints We are often...

Page 5: ...adiators etc Blown fuses must be replaced by fuses of the correct rating Please refer to the SPECIFICATIONS section for the applicable rating For connection to the mains use the enclosed power cord wi...

Page 6: ...at the unit can easily be disconnected from the mains by means of a plug or an all pole mains switch on the back side Please note Switching the POWER switch off does not disconnect the unit completely...

Page 7: ...onnected in series to mix outputs or integrated into the insert path of a mixing console Avoid parallel use in the Aux path as with an effects unit since this mixes the original signal with the proces...

Page 8: ...lements on the SU9920 it is easy to learn to use it Perform the following steps 1 Connect the unit according to the application as described in section 3 1 2 Switch on all devices amplifier and loudsp...

Page 9: ...a high level of security against interference signals such as noise interference from power cables and they should be used for all long cable routes Fig 4 2 Balanced 1 4 TRS jack plugs Alternatively y...

Page 10: ...N 0 05 typ 4 dBu 1 kHz IN OUT Crosstalk 75 dB POWER SUPPLY Mains voltage USA Canada 120 VAC 60 Hz China Korea 220 VAC 50 60 Hz Europe UK Australia 230 VAC 50 Hz Japan 100 VAC 50 60 Hz Export model 12...

Page 11: ...rnational GmbH ALL RIGHTS RESERVED c 2007 BEHRINGER International GmbH BEHRINGER International GmbH Hanns Martin Schleyer Str 36 38 47877 Willich Muenchheide II Germany Tel 49 2154 9206 0 Fax 49 2154...

Page 12: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourag...

Reviews: