background image

2

EURORACK UB1002FX/UB1202FX

This symbol, wherever it appears, alerts you to the

presence of uninsulated dangerous voltage inside

the  enclosure—voltage  that  may  be  sufficient  to

constitute a risk of shock.

This  symbol,  wherever  it  appears,  alerts  you  to

important operating and maintenance instructions

in  the  accompanying  literature.  Please  read  the

manual.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION:

To reduce the risk of electric shock, do not remove

the  top  cover  (or  the  rear  section).  No  user

serviceable parts inside; refer servicing to qualified

personnel.

WARNING:

To reduce the risk of fire or electric shock, do not

expose  this  appliance  to  rain  and  moisture.  The

apparatus  shall  not  be  exposed  to  dripping  or

splashing  and  no  objects  filled  with  liquids,  such

as vases, shall be placed on the apparatus.

DETAILED SAFETY INSTRUCTIONS:

1)  Read  these  instructions.

2)  Keep  these  instructions.

3)  Heed  all  warnings.

4)  Follow  all  instructions.

5)  Do  not  use  this  apparatus  near  water.

6)  Clean  only  with  dry  cloth.

7)  Do  not  block  any  ventilation  openings.  Install  in

accordance  with  the  manufacturer’s  instructions.

8) Do not install near any heat sources such as radiators,

heat  registers,  stoves,  or  other  apparatus  (including

amplifiers)  that  produce  heat.

9)  Do  not  defeat  the  safety  purpose  of  the  polarized  or

grounding-type  plug.  A  polarized  plug  has  two  blades

with  one  wider  than  the  other.  A  grounding  type  plug

has  two  blades  and  a  third  grounding  prong.  The  wide

blade  or  the  third  prong  are  provided  for  your  safety.  If

the  provided  plug  does  not  fit  into  your  outlet,  consult

an  electrician  for  replacement  of  the  obsolete  outlet.

10)  Protect  the  power  cord  from  being  walked  on  or

pinched  particularly  at  plugs,  convenience  receptacles,

and  the  point  where  they  exit  from  the  apparatus.

11)  Only  use  attachments/accessories  specified  by  the

manufacturer.

12)  Use  only  with  the  cart,  stand,  tripod,  bracket,  or  table

specified  by  the  manufacturer,  or  sold  with  the

apparatus. When a cart is used, use caution when moving

the  cart/apparatus  combination  to  avoid  injury  from

tip-over.

13)  Unplug  this  apparatus  during  lightning  storms  or

when  unused  for  long  periods  of  time.

14)  Refer  all  servicing  to  qualified  service  personnel.

Servicing  is  required  when  the  apparatus  has  been

damaged  in  any  way,  such  as  power  supply  cord  or  plug

is damaged, liquid has been spilled or objects have fallen

into  the  apparatus,  the  apparatus  has  been  exposed  to

rain  or  moisture,  does  not  operate  normally,  or  has  been

dropped.

15)  CAUTION  -  These  service  instructions  are  for  use  by

qualified  service  personnel  only.  To  reduce  the  risk  of

electric  shock  do  not  perform  any  servicing  other  than

that  contained  in  the  operation  instructions  unless  you

are  qualified  to  do  so.

Summary of Contents for EURORACK UB1002FX

Page 1: ...EURORACK UB1002FX UB1202FX Version 1 0 February 2005 User s Manual ENGLISH...

Page 2: ...purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the thi...

Page 3: ...ative technologies such as the completely new IMP Invisible Mic Preamps guarantee optimum sound quality and extraordinarily high quality components provide unrivalled reliability even under extreme lo...

Page 4: ...rossover amplifier The interface of BEHRINGER mixing consoles is optimized for these tasks enabling you to easily keep track of the signal path 1 INTRODUCTION 1 2 The user s manual The user s manual i...

Page 5: ...alue ranges the first value range 10 to 60 dB refers to the MIC input and shows the amplification for the signals fed in there The second value range 10 to 40 dBu refers to the line input and shows it...

Page 6: ...of both headphones and main monitor outputs MAIN OUT The MAIN OUT connectors are unbalanced mono connectors The main mix signal appears here at a level of 0 dBu The MAIN MIX fader adjusts the volume o...

Page 7: ...VEL INDICATOR The 4 segment display accurately displays the relevant signal level LEVELSETTING To correctly set the gains of the channels first set the LEVEL controls of the input channels to their ce...

Page 8: ...SIGNAL and CLIP LED The SIGNAL LED on the effects module shows the presence of a signal whose level is high enough This LED should always be on However make sure that the CLIP LED lights up only spor...

Page 9: ...utputs of the sound card in your computer to the CD tape inputs Recording and playback Once in the mixing console the recording signal is pre amplified EQ ed and is then routed to the main bus Use the...

Page 10: ...the way down counterclockwise to avoid creating a feedback loop 4 INSTALLATION 4 1 Mains connection AC POWER IN Connect the power supply to the 3 pin mains connector on the rear of the console Use th...

Page 11: ...B 137 dB A weighted 50 source resistance 130 dB 133 9 dB A weighted 150 source resistance 127 1 dB 130 9 dB A weighted Frequency response 10 Hz 200 kHz 1 dB Gain range 10 to 60 dB Max input level 12 d...

Page 12: ...ded from this warranty in particular if caused by improper handling of the product by the user This also applies to defects caused by normal wear and tear in particular of faders crossfaders potentiom...

Reviews: