Important Safety Instructions

This symbol, wherever it appears, alerts you to the 

 

*

presence of uninsulated dangerous voltage inside the 

enclosure - voltage that may be sufficient to constitute 

a risk of shock.

This symbol, wherever it appears, alerts you to im-

 

!

portant operating and maintenance instructions in the 

accompanying literature.  Please read the manual.

Caution

To reduce the risk of electric shock, do not remove the 

 

+

top cover (or the rear section).  No user serviceable parts 

inside.  Refer servicing to qualified personnel.

Caution

To reduce the risk of fire or electric shock, do not expose 

 

+

this appliance to rain and moisture.  The apparatus shall 

not be exposed to dripping or splashing liquids and no 

objects filled with liquids, such as vases, shall be placed 

on the apparatus.

Caution

These service instructions are for use by qualified ser

-

 

+

vice personnel only.  To reduce the risk of electric shock 

do not perform any servicing other than that contained in 

the operation instructions. Repairs have to be performed 

by qualified service personnel.

Read these instructions.

1) 

Keep these instructions.

2) 

Heed all warnings.

3) 

Follow all instructions.

4) 

Do not use this apparatus near water.

5) 

Clean only with dry cloth.

6) 

Do not block any ventilation openings.  Install in accor-

7) 

dance with the manufacturer’s instructions.

Do not install near any heat sources such as radiators, 

8) 

heat  registers,  stoves,  or  other  apparatus  (including 

amplifiers) that produce heat.

Do  not  defeat  the  safety  purpose  of  the  polarized  or 

9) 

grounding-type plug.  A polarized plug has two blades 

with  one  wider  than  the  other.   A  grounding-type  plug 

has two blades and a third grounding prong.  The wide 

blade or the third prong are provided for your safety.  If 

the provided plug does not fit into your outlet, consult an 

electrician for replacement of the obsolete outlet.

Place the power cord so that it is protected from being 

10) 

walked on and sharp edges. Be sure that the power cord is 

protected particularly at plugs, convenience receptacles 

and the point where it exits from the apparatus.

The  apparatus  shall  be  connected  to  a  MAINS  socket 

11) 

outlet with a protective earthing connection.

Where the MAINS plug or an appliance coupler is used 

12) 

as  the  disconnect  device,  the  disconnect  device  shall 

remain readily operable.
Use  only  attachments/accessories  specified  by  the 

13) 

manufacturer.

Use  only  with  the  cart,  stand,  tripod,  bracket,  or  table 

14) 

specified by the manufacturer, or sold with the apparatus.  

When a cart is used, use caution when moving the cart/

apparatus combination to avoid injury from tip-over.

Unplug this apparatus during lightning storms or when 

15) 

unused for long periods of time.

Refer all servicing to qualified service personnel.  Servic

-

16) 

ing is required when the apparatus has been damaged in 

any way, such as power supply cord or plug is damaged, 

liquid has been spilled or objects have fallen into the appa-

ratus, the apparatus has been exposed to rain or moisture, 

does not operate normally, or has been dropped.

Summary of Contents for Eurodesk SL2442FX-Pro

Page 1: ...EURODESK SL3242FX PRO SL2442FX PRO User Manual A50 24413 00002...

Page 2: ...sters stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or 9 grounding type plug A polarized plug has two blades with one wider than th...

Page 3: ...make it to produce such high grade devices at such unbelievably low prices The answer is quite simple it s you our customers Many satisfied customers means large sales volumes enabling us to get bette...

Page 4: ...ur dealer and the shipping company im mediately otherwise claims for damage or replacement may not be granted We recommend that you use a flight case to give the unit optimum protection during use or...

Page 5: ...lly counter clockwise connect the external device and adjust the output level recommended by the manufacturer If available the output level display of the external device should read 0 dB with signal...

Page 6: ...ignal to the solo bus Solo In Place or the PFL bus Pre Fader Listen Thus you can monitor a channel signal without affecting the main output signal The signal to be monitored is taken either pre PFL mo...

Page 7: ...bgroups 1 4 Fig 2 9 The EURODESK has 4 subgroups enabling you to create mono or stereo mixes from multiple input signals Subgroups are controlled from one mono or two stereo subgroup faders Additional...

Page 8: ...h a nominal operating level of 4 dBu and provide the main mix signal Main out connectors and main insert Fig 2 15 35 The MAIN OUT 1 4 TRS connectors outputs also provide the main mix signal 36 Like th...

Page 9: ...switched on and the first to be switched off Always make sure that the appropriate volume is set CD tape 2 7 CD tape Fig 2 20 47 TO MAIN controls the volume of for example a CD player connected to the...

Page 10: ...s from the input channels When neither of the FX SEND controls is turned up the effects processor will not receive a signal 61 Turn the FX 1 or FX 2 control to select an effects preset Then push it br...

Page 11: ...as reverb chorus flanger delay and a variety of combination effects from our renowned studio effects processor VIRTUALIZER PRO DSP2024P Use theFX control on the channels and the FX SEND control to sup...

Page 12: ...compressor is used only for the bass which is why this input channel is separate from all buses SUB and MAIN switch not pressed The bass signal is directly routed from the built in effects processor t...

Page 13: ...L overhead R are mixed down to two subgroups and then routed to the main mix This way it is possible to conveniently control the volume of the entire drums in the main mix with the two subgroup faders...

Page 14: ...balanced and unbalanced connectors The tape ins and outs are stereo RCA connectors Please ensure that only qualified personnel install and operate the EURODESK During installation and opera tion the...

Page 15: ...erb Flanger combined with a reverb effect All purpose effect Phaser Reverb Phaser combined with a reverb effect All purpose effect Rotary Speaker Reverb Rotary Speaker effect combined with reverb Orga...

Page 16: ...ck unbalanced Impedance approx 120 Max output level 22 dBu Main outputs XLR Type XLR connector electronically balanced Impedance approx 240 balanced 120 unbalanced Max output level 28 dBu Main outputs...