7.0 Technical data
(at 23° C % 5° C, max. 75 % rel. humidity)
Display: ..............................3
3/4
, LCD incl. funktions and
symbols
Bargraph: ............................40 segments
Range Selection: ................manuel/ frequenzy: autom.
Auto-Power-Off: ..................approx. 30 min. After the dis-
engaging, the device can be turned on after ca. 10 seconds
again.
Überlaufanzeige: ................the left digit is blinking
Measuring rate: ..................20 measurements/sec. (Bar-
graph) 2 measurements/sec.
(LCD)
max. Leiterdurchmesser: ....ca. 23 mm
Overvoltage Categorie: ........CAT II, 600 V
Pollution degree: ................2
Hight above MSL.: ..............up to 2000 m
Battery display: ..................at low battery
Power supply: ....................Batterie 1,5 V IEC LR6 (alka-
line)
Current Consumtion: ..........approx. 10 mA
Operation temperature: ......-10° C … 50° C
Storage temperature: ..........20° C … 60° C
Humidity: ............................< 75 % relative humidity
Dimension:..........................183 x 63,6 x 35,6 mm
Wight: ................................ca. 190 g
Current AC
Range
Resolution
Accuray
50 Hz/60 Hz
40 Hz … 1 kHz
AC 0 – 40 mA
10 µA
±(1,5 % rdg. +3 D)
±(2,0 % rdg. +5 D)
AC 0 – 400 mA
100 µA
±(1,5 % rdg. +3 D)
±(2,0 % rdg. +5 D)
AC 0 – 4 A
1 mA
±(1,5 % rdg. +3 D)
±(2,0 % rdg. +5 D)
AC 0 – 40 A
10 mA
±(1,5 % rdg. +3 D)
±(2,0 % rdg. +5 D)
AC 0 – 50 A
0,1 A
±(1,5 % rdg. +5 D)
±(2,0 % rdg. +5 D)
AC 50 – 60 A
0,1 A
±(3,0 % rdg. +5 D)
±(3,5 % rdg. +5 D)
Voltage AC
Range
Resolution
Accuray
50 Hz/60 Hz
40 Hz … 1 kHz
0...400 V
0,1 V
±(1,0 %
rdg.
+3 D)
±(2,0 %
rdg.
.± 4 D)
Technical data
26