
11.0 Technical Data
General
Display ................................................................................4
1/2
digit LCD, 19999 digits
Interface..............................................................................RS 232
Memory capacity ................................................................> 500 data strings (length determination)
Battery status indication......................................................display of battery symbol
Auto-Power-Off ..................................................................after approx. 5min
Battery supply ....................................................................1 x 9 V, IEC 6LR61
Battery life ..........................................................................for average usage approx. 1 year
Current consumption ..........................................................25mA during measurement, max. 120mA
Dimensions ........................................................................193 x 91 x 50mm
Weight ................................................................................approx. 510g
Ambient Conditions:
Operation temperature Cable Length Meter ........................0°...40° C (0...70% rel. humidity)
Storage temperature Cable Length Meter ............................-20...60° C (0...80% rel. humidity)
Cable temperature ranges ..................................................-20...90° C
Height above sea level ........................................................up to 2000m
Cable Length Measurement
(fixed measurement ranges TAB I and TAB II)
Conductor cross section ....................................................0.05...500mm2
............................................................................................AWG 28... AWG 4/0
............................................................................................MCM 250... MCM 500
Ranges................................................................................56 cross sections / cable types
Measurement ranges / resolution........................................0.1 m...1999.9m / 0.1m
............................................................................................1 m...19999m / 1m
Measurement range selection ............................................automatic
Accuracy ............................................................................±(2% rdg. + 5 digits)
30
Technical Data
Summary of Contents for Unitest 2005
Page 17: ...UNITEST Cable Length Meter 3000 Instruction Manual Cat No 2005 ...
Page 33: ...UNITEST Câblemètre 3000 Mode d emploi Réf 2005 ...
Page 49: ...UNITEST Medidor de cables 3000 Manual de instrucciones no de ref art 2005 ...
Page 66: ...66 ...
Page 68: ...68 Änderungen vorbehalten 03 2001 PTDB2005 00 Reg No 3335 ...