![Beha-Amprobe AT-6010-EUR User Manual Download Page 29](http://html.mh-extra.com/html/beha-amprobe/at-6010-eur/at-6010-eur_user-manual_2721325029.webp)
25
6. SPECIFICATIONS
Features
AT-6010-RE
AT-6010-TE
CT-400-EUR
Measurement
Category
CAT III 600 V
CAT III 600 V
CAT IV 600 V,
CAT III 1000 V
Operating
Voltage
0 to 600 V AC/DC
0 to 600 V AC/DC
0 to 1000 V AC
Operating
Frequency
Energized: 6.25 kHz
De-Energized: 32.768 kHz
Energized: 6.25 kHz
De-Energized: 32.768 kHz
Wire tracing: 32.768 kHz
AC current measurement:
45 Hz to 400 Hz
Voltage Detection N/A
> 30 V AC/DC
N/A
Signal Indications Numeric bar graph display
and audible beep
LEDs
N/A
Response Time
Tip Sensor (Energized /
De-energized): 500 ms
Battery voltage monitoring:
5 sec
Line/phase voltage
monitoring: 1 sec
Battery voltage monitoring:
5 sec
Instantaneous
Current Output of
Signal (typical)
N/A
Energized circuit:
HI mode: 60 mA RMS
De-energized circuit:
HI mode: 130 mA RMS
Loop mode: 160 mA RMS
1 mA/A for AC current
measurement with
multimeter
Signal Voltage
Output (nominal)
N/A
De-energized circuit:
HIGH: 33 V RMS, 140 Vp-p
With CT-400-EUR:
Loop model:
31 V RMS, 120 Vp-p
De-energized circuit:
2.4 V RMS, 24 Vp-p
Range Detection
(open air)
Tip Sensor (Energized):
Max distance via air:
up to 6.1 m (20 ft)
Pinpointing:
approx. 5 cm (1.97 in)
Tip Sensor (De-energized):
Max distance via air:
up to 4.5 m (14.7 ft)
Pinpointing:
approx. 5 cm (1.97 in)
N/A
N/A