USAGE
A socket-check adapter or light-
check adapter can be connected
with 4 mm safety test leads with a
test and measuring instrument, e.g.
installation testers.
The adapters are only for conducting
tests by trained people.
The adapters must not be used to
connect appliances to mains voltage.
The adapters are not designed for
continuous operation.
LIGHT-CHECK-ADAPTER
1. Select the correct adapter for
the light socket to be tested.
2. Separate the light socket from mains.
3. Remove the bulb.
4. Put the adapter into the socket
of the bulb.
5. Phase and neutral are marked at
adapters E27 and E14:
a. Brown: Phase
b. Blue: Neutral
6. Phase and neutral cannot be
marked for adapters B22, B15
and GU10 due to geometry of
these sockets. Detect phase and
neutral by using a suitable tester
if necessary, e.g. a two-pole
voltage tester.