8
Voltage detection
Automatic
Polarity detection
Full range
Range detection
Automatic
Automatic load
(RCD trip test)
Yes
Internal load
Approximately 2.4 W at 690 V (load
buttons activated)
Current Is
<3.5 mA at 690 V (load buttons
activated
Connectable load
Approximately 240 W at 690 V
Test current
connectable load
<350 mA
Operation time
(DT)
30 s
Recovery time
240 s
Automatic power
on
>12 V
(activated load buttons)
>24 V
(w/o load buttons)
Data Hold
(2100-Beta only)
12...690V AC/DC
Single Pole Phase Test
Voltage range
180…690 V AC against earth
Frequency range
40 Hz…70 Hz
Acoustic
indication
yes
LED indication
Red LED
Continuity Test
Range
0….500 k
Ω
Tolerances
0% to +50%
Test current
<5 μA
Acoustic
indication
yes
LED indication
Red LED
Overvoltage
protection
690 V AC/ DC
Automatic power
on
< 500 k
Ω
Rotary Field Detection
Voltage range
340…440 V AC phase to phase
Frequency range
47 Hz…63 Hz
LED indication
Red LED
General Specifications
Operating
temperature
range
-15°C to +55°C
Storage
temperature
range
-15°C to +55°C
Humidity
Max. 95% RH
Operating
altitude
Up to 2000 m
Measurement
category
CAT IV 600V,
CAT III 690V
Pollution degree
2
IP Protection
IP 64
Safety
regulations
EN 61243-3:2010
Agency approval
GS from TÜV Rheinland, CE
Power Supply
2x 1.5V (AAA/ IEC LR03)