8A

 3. Lamp  

 

 

 
 

 Lamp :   

 

ELC 24V 250W 

 
1. Always switch off the main supply and never handle the lamp or luminaries when is 

hot. 

2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured 

alcohol and wipe it with a lint free cloth before installation. 

3. Never operate the lamp without appropriate shielding. 
4. Make sure the lamp is located in the center for the best spot. 
 
Diagram for Lamp changing   

 

  4. How To Set The Unit   

 

 4.1 Control Panel  

 

Display 

To show the various menus and the selected functions. 

LED 

 DMX 

 On 

 DMX input present 

 MASTER   On 

 Master Mode 

 SLAVE 

 On 

 Slave Mode 

 SOUND 

 Flashing 

 Sound activation 

Button 

  MENU 

  To select the programming functions 

  DOWN 

  To go backward in the selected functions 

  UP 

  To go forward in the selected functions 

  ENTER 

  To confirm the selected functions 

 

Remote controller input 

By connect to the 1/4” microphone jack to control the unit for stand by, function and mode 

Sensitivity 

To adjust the sound sensitivity. 

Microphone 

To receive audio signal for sound activation. 

DMX input/output 

For DMX512 link, use 3-pin XLR plug cable to link the unit together. 
 

In case of replacement of the lamp or maintenance, do not open the 

  fixture within 15 minutes until the unit cools down after switching off.

Summary of Contents for iSolution IMOVE-5S

Page 1: ...e 20mm Glass 6 3A Fast Blow 20mm Glass 5A Fast Blow Lamp ELC 24V 250W Dimension 290mm x 330mm x 380mm Weight 12 kg BEGLEC CVA t Hofveld 2 B1702 Groot Bijgaarden WWW BEGLEC COM Innovation Quality Performance IMOVE 5S IMOVE 5W User Guide Professional Entertainment Technology ...

Page 2: ...with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 1 1993 EN61000 3 2 1995 EN61000 3 3 1995 EN55014 2 1997 CATEGORY II EN61000 4 2 1995 EN61000 4 3 1995 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1995 EN61000 4 11 1994 Harmonized Standard EN60598 1 1993 Safety of household and similar electric...

Page 3: ...e and screwed it Note do not press the belt 7 Put the belt around the axis gear and motor gear 8 Plug all the connect wires C that form the arm to PC board and ignitor 9 Adjust the pan home position 10 Screw the base housing cover B TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 2 1 Beam Angel 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 5 How To Control The U...

Page 4: ...pare parts Don t connect the device to any dimmer pack or power pack Do not touch any wire during operation as high voltage might be causing electric shock 6 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2...

Page 5: ...o have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Warning To pr...

Page 6: ...istent DMX channel enable iRock iShow and iMove to be link together Features different preprogrammed chase patterns Please use a 3 pin XLR cable plug when connecting units together Accurate focusable optics system and ultra smooth stepping motors Fan cooling Pan 540 deg Tilt 270 deg Dimension 290 x 330 x 380 mm Weight 12 kg IM 5S Independent gobo wheel with 14 gobos plus open and blackout includin...

Page 7: ...ing Slow Sound 3 LED on Position Latch LED fast blinking 5 3 1 iSolution Operation Consistent DMX configuration enable iMove to be linked together with iRock and iShow and controlled at the same time DMX address can be set remotely by iLead controller please refer to the user manual of iLead controller No need to calculate the DMX channels of each fixture in the chain Automatic switching between D...

Page 8: ...ED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microphone jack to control the unit for stand by function and mode Sensitiv...

Page 9: ...ly 5 2 Easy Controller The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit you will find that the remote control on the first unit will control all the other units for Stand by Strobe Next and Fast Slow function Display Inversion It is good for you to install the unit on the floor or under ceiling Press the MENU button up to when the...

Page 10: ...8 seconds To go back to the functions without any change press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 mode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angel left to right to left 160 Tilt mov...

Page 11: ...t any change after 8 seconds To go back to the functions without any change press the MENU button again Tilt Inversion Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or tilt inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main fu...

Reviews: