background image

DETAIL  A

SCALE .75

A

1

1

2

2

3

3

4

4

A

A

B

B

C

C

D

D

This document is the property of and contains information proprietary to Beghelli Canada, Inc. It is submitted in confidence and is to be used solely for the 

purpose for which it was furnished and returned upon request. This document and such information is not to be reproduced, transmitted, disclosed, or used

otherwise in whole or in part without prior authorization of Beghelli Canda, Inc. The recepient's acceptance of this document shall be considered an 

agreement to the foregoing.

UNLESS OTHERWISE SPECIFIED

ALL DIMENSIONS = INCHES
 1/2

TOLERANCES: 

         .X  = 

 .020

       .XX  = 

 .010

     .XXX  = 

 .005

   .XXXX  = 

 .003

3900 14Th. Avenue

Markham Ontario, L3R 4R3

Tel. # 905 948-9500 Fax # 905 948 8673

email: [email protected]

Web: http://www.beghelli.com

MATERIAL

FINISH

DRAWN BY

DATE

SIZE

SCALE

REV

SHEET

PART NAME

DWG NO

REF NO

DO NOT SCALE

EDGELIT COMBO SURFACE 

INSTRUCTION

 

 

11/20/2012

 

 

 

 

 

PART #

 

L D

1
2

3

1

WHITE NEUTRAL

2

BLACK 120VAC

3

ORANGE/RED 277/347VAC

LED BOARD LEAD WIRES

TO SOURCE

WHITE NEUTRAL

BLUE HOT

2

1

1

2

926000351

REFERENCE

POINT

REFERENCE

POINT

E

XIT

EXI

T

CHEVRON PLACEMENT TEMPLATE

PLACE TEMPLATE ON SIGN FACE

ALIGN TO THE TOP LEFT HAND

CORNER OF “E”

PLACE TEMPLATE ON SIGN FACE

ALIGN TO THE TOP RIGHT HAND

 CORNER OF “T”

Chassis GND

GREEN Ground

BLACK 120VAC

RED 347VAC or ORANGE 277VAC

WHITE Neutral

LED Board

AC & UNIVERSAL DC SIGN

YELLOW Positive 6 to 24VDC

PURPLE Negative

Emergency Supply
FROM Battery Pack

NOTE: Cap unused AC Wire!

24 hours
Unswitched Supply

Chassis GND

LED Board

AC ONLY SIGN

NOTE: Cap unused AC Wire!

GREEN Ground

BLACK 120VAC

RED 347VAC or ORANGE 277VAC

WHITE Neutral

24 hours
Unswitched Supply

SELF-POWERED SIGN

Chassis GND

LED Board

NOTE: Cap unused AC Wire!

GREEN Ground

BLACK 120VAC

RED 347VAC or ORANGE 277VAC

WHITE Neutral

24 hours
Unswitched Supply

Ni-Cd

Battery

Figure 1

Figure 2

Figure 3

Screw canopy
into spider plate

Screw canopy
into mounting 
plate

Squeeze Tension Spring Clip 

Together To Remove/Install 

Cover Exit Assembly

TEST

CHARGE

AC ON

WHITE - Neutral / Common

GREEN - Ground

BATTERY

NEG

-

POS

+

BATTERY -

LAMP +

LAMP 

-

CHARGER PC BOARD

ASSEMBLY

LAMPS

STANDARD TRIPLE INPUT VERSION 

RED - 347V Line / Hot

FUSE

CHARGER BOARD

BLACK - 120V Line / Hot

ORANGE - 277V Line / Hot

Figure 2

Figure 3

Figure 1

Figure 4

Spring Clip

Installed In Tab

Insert/Remove One Side of 

Clip Under Tab Then Insert/

Remove The Other Side

08/15/2016

Summary of Contents for GDE Combo

Page 1: ...secured through these holes and then to a secure mounting above the suspended ceiling figure 2 5 Make proper wiring connections between the AC supply and the unit s transformer per diagram provided figure 3 Insulate unused wire Connect ground to supplied green ground wire in accordance with local codes Reassemble all wire connections and connectors CAUTION Failure to insulate unused wire may resul...

Page 2: ...d otherwise in whole or in part without prior authorization of Beghelli Canda Inc The recepient s acceptance of this document shall be considered an agreement to the foregoing UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS INCHES ANGLES 1 2 TOLERANCES X 020 XX 010 XXX 005 XXXX 003 3900 14Th Avenue Markham Ontario L3R 4R3 Tel 905 948 9500 Fax 905 948 8673 email sales beghellicanada com Web http www begh...

Page 3: ...battery is not connected 4 Battery is severely discharged Allow 24 hours for recharge and then retest NOTE This could be the result of a switched AC supply to the unit which has been turned off at some point a battery with a shorted cell an old battery or a battery which has been discharged due to a long power outage and is not yet fully recharged EMERGENCY LAMPS COME ON DIM WHEN TEST BUTTON IS PR...

Page 4: ...onnect ground to supplied green ground wire in accordance with local codes Reassemble all wire connections and connectors CAUTION Failure to insulate unused wire may result in a shock hazard or unsafe condition as well as equipment failure 6 Uncoil the wire lead s from the Positive circuit board terminal and connect to the positive terminal connector on the battery figure 3 7 Remove plastic bag su...

Page 5: ...NT TEMPLATE PLACE TEMPLATE ON SIGN FACE ALIGN TO THE TOP LEFT HAND CORNER OF E PLACE TEMPLATE ON SIGN FACE ALIGN TO THE TOP RIGHT HAND CORNER OF T Chassis GND GREEN Ground BLACK 120VAC RED 347VAC or ORANGE 277VAC WHITE Neutral LED Board AC UNIVERSAL DC SIGN YELLOW Positive 6 to 24VDC PURPLE Negative Emergency Supply FROM Battery Pack NOTE Cap unused AC Wire 24 hours Unswitched Supply Chassis GND L...

Page 6: ...battery is not connected 4 Battery is severely discharged Allow 24 hours for recharge and then retest NOTE This could be the result of a switched AC supply to the unit which has been turned off at some point a battery with a shorted cell an old battery or a battery which has been discharged due to a long power outage and is not yet fully recharged EMERGENCY LAMPS COME ON DIM WHEN TEST BUTTON IS PR...

Reviews: