background image

BBX

-SE

BBX-SE-HO

 

Pag

2

 of 

2

Beghelli U.S.A., 3810 Executive Way, Miramar, Florida, Tel: (954) 442-6600

04/21/22

4.

Autotest of Remote Lamps 

(when applicable):

In order to connect remote lamp heads to Autotest circuit, follow these instructions.

(1) Remove ground male connector from the

female connector.

(2)

Plug the remote male connec

tor int

o the

female connector.

(3)

Connect extended remote head wires to

the remote wires using wire nut

s

.

 

Yellow

is po) and

 

Purple

 

is

 

negative(-).

WARNING
1) Make sure that power is off before making any electrical connections!!
2) Unused wires must be capped using wire nuts.

AC INPUT

White Neutral
Black 120-277VAC

Integral

LED Head

Remote Heads

(Option)

Battery

Ground