If you install the hob above a built-in oven, both the hob and
the built-in oven must be connected to the mains separately.
Proper ventilation
The hob must be ventilated properly. The air inlet (D) and
outlet (E) must never be blocked or covered (s. fig. below).
Always keep the appliance in proper condition.
A
Wall cupboard = min. 450 mm
Extractor hood = min. 760 mm
B
min. 50 mm
C
Ventilation slot = min. 30 mm
D
Air inlet
E
Air outlet = min. 5 mm
Installation
(1)
Before installing the hob, the adhesive seal has to be fixed on
the bottom edge of the hob properly.
The seal has to be fixed properly. The outer side of the seal
must match the bottom outer edge of the hob (s. fig.
below). The seal must be fitted tightly on the bottom edge
of the hob (no overlaps, no gaps etc.) to prevent liquids etc.
from entering the installation opening subsequently.