BEDU A Series Operating Instructions Manual Download Page 5

GB

animals and objects.

The manufacturer declines any liability in the event of 

damage due to improper use or use under conditions 

other than those indicated on the name-plate and in 

these instructions.

i

  Follow the routine maintenance schedules and

the promptly replace damaged parts, this will

allows the device to work in the best conditions.

Use only original spare parts provided from 

Bedu

 

Pompen BV

 or from an authorized distributor.

  Don’t  remove  or  change  the  labels  placed  on 

the device. 

Do not start the device in case of defects or damaged 

parts.

  Maintenance operations, requiring full or partial 

disassembly of the device, must be done only 

after disconnection from the supply.

4.2. Safety devices

The device has an external case that prevents any 

contact with internal parts.

4.3. Residual risks

The appliance, designed for use, when used in-line with 

the design and safety rules, doesn’t have residual risks.

4.4. Information and Safety signals

For this kind of product there will not be any signals on 

the product.

4.5. Individual protection devices

During installation, starting and maintenance it is 

suggested to the authorized operators to consider  

the use of individual protection devices suitable for 

described activities.

During ordinary and extraordinary maintenance 

interventions, where it is required to remove the filter, 

safety gloves are required.

Signal  

individual protection device

HAND PROTECTION

 

(gloves for protection against chemical, 

thermal and mechanical risks).

5. TRANSPORTATION AND HANDLING

The product is packed to maintain the content intact.

During transportation avoid to stack excessive weights.

Ensure that during the transportation the box cannot

move.

It is not necessary to use any special vehicle to transport 

the packaged device.

The transport vehicles must comply, for the weight and

dimensions, with the chosen product (see technical

catalogue dimensions and weights).

5.1. Handling 

Handle with care, the packages must not receive 

impacts.

Avoid to impact onto the package materials that could 

damage the pump.

If the weight exceeds 25 Kg the package must be 

handled by two person at the same time.

6. INSTALLATION
6.1. Dimensions

For the dimensions of the device (see technical 

catalogue).

6.2.  Ambient requirements and installation site 

dimensions

The customer has to prepare the installation site in 

order to guarantee the right installation and in order to 

fulfill the device requirements (electrical supply, etc...).

The place where the device will be installed must fulfill 

the requirements in the paragraph 3.2.

It's Absolutely forbidden to install the machine in an 

environment with potentially explosive atmosphere.

6.3. Unpacking

i

  

Inspect the device in order to check any

damages which may have occurred during

transportation.

Package material, once removed, must be discarded/

recycled according to local laws of the destination 

country.

6.4. Installation

The pumps must be installed with the rotor axis in the 

horizontal position and with the feet under the pump.

Provide enough clearance around the unit for motor 

ventilation and for filling and draining the pump.

6.4.1. Pipes

Ensure the insides of pipes are clean and unobstructed 

before connection.

ATTENTION: The pipes connected to the pump 

should be secured to rest clamps so that they do 

not transmit stress, strain or vibrations to the pump 

(par. 12.3 fig. 1). 

Tighten the  pipes or union coupling to the extent 

sufficient to ensure a tight seal.

Excessive torque may cause damage to the pump.

When the pipe or union coupling is mounted, keep 

the pump casing connection blocked with a second 

wrench, making sure the connection is not deformed by 

excessive tightening.

The pipe diameters must not be smaller than the pump 

connections.

6.4.2. Suction pipe

The suction pipe must be perfectly airtight.

If operating with flexible hoses use a semi rigid suction 

hose, in order to avoid the hose narrowing due to 

suction vacuum.

With the liquid level on the suction side above the pump 

(inflow  under  positive  suction  head,  fit  an  inlet  gate 

valve.

Follow  local  specifications  if  increasing  network 

pressure.

6.4.3. Delivery pipe

Fit a gate valve in the delivery pipe to adjust delivery 

and head.

Install a pressure gauge.

Summary of Contents for A Series

Page 1: ...OPERATING INSTRUCTIONS Self priming centrifugal pumps with open impeller A AS ...

Page 2: ......

Page 3: ...electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise p...

Page 4: ...nder conditions other than those indicated in these instructions Improper use of the product reduces the safety and the efficiency of the device Bedu shall not be responsible for failure or accident due to improper use Do not use in ponds tanks or swimming pools or where people may enter or come into contact with the water 2 3 Marking The following picture is a copy of the name plate see Pic 1 tha...

Page 5: ...cts Avoid to impact onto the package materials that could damage the pump If the weight exceeds 25 Kg the package must be handled by two person at the same time 6 INSTALLATION 6 1 Dimensions For the dimensions of the device see technical catalogue 6 2 Ambient requirements and installation site dimensions The customer has to prepare the installation site in order to guarantee the right installation...

Page 6: ...t least 3 mm in all poles With a three phase motor install an overload protection device with curve D appropriate for the rated current of the pump Single phase AM are supplied with a capacitor connected to the terminals and for 220 240 V 50 Hz with an incorporated thermal protector 7 STARTUP AND OPERATION 7 1 Preliminary checks before start up of the pump Do not start up the device in case of dam...

Page 7: ...re not described in this manual must be made only by special personnel authorized by Bedu Pompen BV For further technical information regarding the use or the maintenance of the device contact Bedu Pompen BV 8 1 Routine maintenance OFF Before every maintenance operations disconnect the power supply and make sure that the device could not accidentally operate Never introduce fingers in the inspecti...

Page 8: ...cessary replace it See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of the rotor 4c Rotor deteriorated 4d Worn rotor and pump case 4e Excessive viscosity of the liquid pumped if other than water 4f Incorrect direction of rotation 4g Suction head excessive in relatio...

Page 9: ...中文 A AS Rev14 indd 安装使用手册 页码 61 64 12 3 Installation examples Hs 0 5 m 3 93 021 2 3 93 021 2 3 93 021 2 Fig 1 Supports and clamps for pipelines 管路的支撑和固定 Fig 2 Filling 灌泵 Fig 3 Draining ...

Page 10: ...0 00 90 04 82 00 76 04 76 20 81 00 78 00 73 00 76 54 98 08 14 20 36 00 14 24 14 74 14 75 88 04 88 00 82 08 76 06 76 16 28 20 98 04 98 00 70 20 32 00 28 00 28 04 14 64 14 60 14 62 14 12 14 13 14 72 14 73 14 70 46 00 32 30 32 32 32 33 14 04 14 04 1 14 00 76 00 1 94 14 64 14 62 14 72 14 73 14 74 32 00 70 18 14 70 14 75 A 65 150 70 00 A 65 150 ...

Page 11: ...4 72 14 74 64 20 68 00 66 16 66 12 68 04 14 60 14 64 14 00 14 04 28 00 28 20 32 00 60 08 60 04 62 04 66 08 66 04 66 00 14 70 14 75 14 12 36 00 14 24 62 00 46 00 62 08 60 00 64 00 14 20 63 00 28 04 68 08 14 62 28 04 28 20 14 12 36 00 14 24 46 00 62 00 63 00 64 00 66 00 68 00 68 16 4 93 146 2 4 93 146 1 AS 50 125 AS 65 150 Alignment of coupling Ευθυγράμμιση ñÂÌÚ Ó Í ÒÓ ËÌÂÌËfl 4 93 125 2 calibro gag...

Page 12: ...netic compatibility Standards EN ISO 12100 2010 EN IEC 60204 1 2006 EN 809 A1 C1 Additional information No further details Declaration We hereby declare under our sole responsibility that the product s mentioned above to which this declaration relates complies with the above mentioned standards and Directives BEDU Pompen BV Poort van Midden Gelderland Rood 10 6666 LT Heteren Tel 31 0 88 4802 900 F...

Page 13: ......

Page 14: ...orking from our own workplace or at your location A fast and appropriate solution for all your issues Wide range of liquid pumps Repair maintenance and revision made for your process BEDU POMPEN B V Poort van Midden Gelderland Rood 10 6666 LT HETEREN Nederland Telefoon 31 0 88 4802 900 E mail info bedu eu WWW BEDU EU BEDU BELGIUM B V B A Industriepark West 75 9100 SINT NIKLAAS België Telefoon 32 0...