© BECOM Systems 2020
20
|
30
Hardware User Manual - Argos3D - P33x
Last change: 29 June 2020/Version 12
6
Appendix
6.1
Operating Conditions
Symbol
Parameter
Min
Typical
Max
Unit
V
IN
Input supply voltage
18
24
30
V
I
IN
Input current at 24V
1.2
1)
4.3
2)
A
I
INT
Input current during integration
5.4
5.5
5.6
A
I
IR
Inrush Current
7.3
T
Operating Temperature
3)
0°
50°
°C
T
Storage Temperature
-40
+85
°C
t
INT
Integration Time
0
7500
µs
FITP
Frame-rate Integration Time Product
780
IP
Ingression protection
IP41
4)
Table 6-1: Operating Conditions
1) Note
Valid for a typical operation condition: frame-rate of 40fps, an integration time of 1000µs and
24V input voltage supply. The input current depends on the applied frame-rate, integration time
and input supply voltage.
2) Note
At maximum Framerate Integration-Time Product (FITP) of 26 fps and 7500µs t
INT
.
3) Note
The maximum operating temperature strongly depends on the FITP.
4) Note
In preferred mounting situation
6.1.1
Input current
The input current depends on the selected frame-rate (fps) and the integration time (t
INT
). The following figure
shows typical values. The values for the x axis shows the FITP which has been calculated with the following
equation:
𝐹𝐼𝑇𝑃 = 𝑡
𝐼𝑁𝑇
[𝑚𝑠] ∙ 𝑓𝑝𝑠 [
1
𝑠
] ∙ 4